Design and Characterization of a Rotating Electrochemical Quartz-Crystal-Microbalance Electrode

نویسندگان

  • P. Kern
  • D. Landolt
چکیده

A novel design for a rotating electrochemical quartz-crystal microbalance (rEQCM) which includes easily and reproducibly exchangeable quartz-crystal holders is described. The rEQCM allows for well-controlled mass-transport conditions at the working electrode on a 10 MHz quartz crystal. Together with the flexibility of the proposed design, this makes it useful for a wide range of applications in electrochemistry. At a data acquisition rate of 5 Hz, noise level and stability of the resonant frequency were better than 1 Hz at rotation rates of 0-3500 rpm. This corresponds to a mass density on the quartz crystal of 4.7 ng cm22. The small recess needed to fix the quartz crystal in the electrode holder was shown not to affect the primary current distribution and the mass-transport conditions. Electrodeposition of Cu and Ag was used for the in situ characterization of the frequency dependence of the Sauerbrey constant (mass sensitivity) of the quartz as a function of mass load on the crystal. It was found that, in the initial phase of Ag and Cu deposition on Au, the mass sensitivity is affected by internal stresses in the deposit. © 2000 The Electrochemical Society. S0013-4651(99)05-039-9. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Catalytic Activity of an Iron-Based Water Oxidation Catalyst: Substrate Effects of Graphitic Electrodes

The synthesis, characterization, and electrochemical studies of the dinuclear complex [(MeOH)Fe(Hbbpya)-μ-O-(Hbbpya)Fe(MeOH)](OTf)4 (1) (with Hbbpya = N,N-bis(2,2'-bipyrid-6-yl)amine) are described. With the help of online electrochemical mass spectrometry, the complex is demonstrated to be active as a water oxidation catalyst. Comparing the results obtained for different electrode materials sh...

متن کامل

Scanning electrochemical microscopy. 36. A combined scanning electrochemical microscope-quartz crystal microbalance instrument for studying thin films.

The design of a combined scanning electrochemical microscope-quartz crystal microbalance (SECM-QCM) with separate potential control of the tip and substrate is described. Both lateral and vertical tip movements near the substrate affect the QCM resonant frequency because of perturbations of the longitudinal and shear waves of the quartz crystal (QC) acoustic wave sensor. The SECM-QCM was used t...

متن کامل

Mechanism of formation and construction of self-assembled myoglobin/hyaluronic acid multilayer films: an electrochemical QCM, impedance, and AFM study.

Self-assembled multilayer films of hyaluronic acid (HA) and the protein myoglobin (Mb) were built up layer by layer on Au covered quartz crystal microbalance (AuQCM) electrode substrates. Film formation and growth were monitored by an electrochemical quartz crystal microbalance (EQCM), and the step-by-step construction was investigated through quantification of the mass variation corresponding ...

متن کامل

Electropolymerization and doping/dedoping properties of polyaniline thin films as studied by electrochemical-surface plasmon spectroscopy and by the quartz crystal microbalance

The electropolymerization and doping/dedoping properties of polyaniline ultrathin films on Au electrode surfaces were investigated by a combination of in situ electrochemical techniques, i.e., electrochemical surface plasmon spectroscopy (ESPR) and the electrochemical quartz crystal microbalance (EQCM). In the ESPR measurements, we employed two wavelengths, i.e., 632.8 and 1152 nm in order to d...

متن کامل

A simultaneous electrochemical impedance and quartz crystal microbalance study on antihuman immunoglobulin G adsorption and human immunoglobulin G reaction.

The quartz crystal microbalance (QCM), in combination with electrochemical impedance spectroscopy (EIS), has been utilized to monitor in situ antihuman IgG (hIgG) adsorption on bare poly(o-phenylenediamine) (PPD)- and 1-dodecanethiol (C12SH)-modified Au electrodes and succeeding human IgG reaction, respectively. The resonant frequency (f) and the motional resistance (R(1)) of the piezoelectric ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000