BACKGROUND Intravascular ultrasound detects stent edge dissections after percutaneous coronary intervention that are not seen angiographically. This study investigated the association between stent edge dissections and clinical outcomes. METHODS AND RESULTS ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a large-scale, prospective, multicenter study of patients undergoing drug-eluting stent implantation. In this prospective substudy, 2062 patients (2433 lesions) were evaluated with intravascular ultrasound to characterize the morphological features and clinical outcomes of stent edge dissection after percutaneous coronary intervention. The prevalence of post-percutaneous coronary intervention stent edge dissection was 6.6% per lesion (161 of 2433). Calcified plaque at the proximal stent edge (relative risk [RR]=1.72; P=0.04) and proximal stent edge expansion (RR=1.18; P=0.004) were predictors for proximal dissection; attenuated plaque at the distal stent edge (RR=3.52; P=0.004), distal reference plaque burden (RR=1.56; P<0.0001), and distal edge stent expansion (RR=1.11; P=0.02) were predictors for distal dissection. At 1-year follow-up, target lesion revascularization was more common in lesions with versus without dissection (5.2% versus 2.7%; P=0.04). Multivariable analysis indicated that residual dissection was associated with target lesion revascularization at 1-year follow-up (RR=2.67; P=0.02). Among lesions with dissection, smaller effective lumen area increased the risk of target lesion revascularization at 1-year follow-up (cutoff value of 5.1 mm(2); P=0.05). CONCLUSIONS Greater stent expansion and the presence of large, calcified, and/or attenuated plaques were independent predictors of stent edge dissection. Residual stent edge dissection, especially with a smaller effective lumen area, was associated with target lesion revascularization during 1-year follow-up after drug-eluting stent implantation. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00638794.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevalence, Features, and Prognostic Importance of Edge Dissection After Drug-Eluting Stent Implantation

The main mechanisms of percutaneous coronary intervention (PCI) with stent implantation are vessel expansion and plaque redistribution, and one of the major complications is dissection originating from the proximal or distal stent edge. Although angiographic criteria for a significant dissection have been published, the criteria for a significant intravascular ultrasound (IVUS)–detected stent e...

متن کامل

Predictors and Long‐Term Clinical Impact of Acute Stent Malapposition: An Assessment of Dual Antiplatelet Therapy With Drug‐Eluting Stents (ADAPT‐DES) Intravascular Ultrasound Substudy

BACKGROUND The impact of acute stent malapposition (ASM) on long-term clinical outcomes in patients undergoing percutaneous coronary intervention is still controversial. We sought to evaluate predictors and long-term clinical outcomes of ASM. METHODS AND RESULTS ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a prospective multicenter study of 8663 patients un...

متن کامل

Pathological Perspective of Drug-Eluting Stent Thrombosis

Although very late stent thrombosis (VLST) after drug-eluting stent (DES) implantation remains a major concern, the precise mechanisms have not been clarified. An association between late acquired incomplete stent apposition (ISA) and VLST of DES has been suggested by several intravascular ultrasound studies demonstrating very high prevalence of ISA in the setting of VLST. To clarify the pathol...

متن کامل

Contemporary Reviews in Interventional Cardiology Edge Effect From Drug-Eluting Stents as Assessed With Serial Intravascular Ultrasound A Systematic Review

Several studies have demonstrated effective reduction of intimal hyperplasia within a drug-eluting stent (DES) when compared with a bare metal stent (BMS), thereby resulting in a lower incidence of target lesion revascularization.1–3 Restenosis at the stent edges, however, is not appreciably reduced by DES. Thus, to understand stent edge effect in DES, it is important to improve the efficacy of...

متن کامل

Coronary restenosis after sirolimus-eluting stent implantation: morphological description and mechanistic analysis from a consecutive series of cases.

BACKGROUND We describe the clinical and morphological patterns of restenosis after sirolimus-eluting stent (SES) implantation. METHODS AND RESULTS From 121 patients with coronary angiography obtained >30 days after SES implantation, restenosis (diameter stenosis >50%) was identified in 19 patients and 20 lesions (located at the proximal 5-mm segment in 30% or within the stent in 70%). Residua...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 9 7  شماره 

صفحات  -

تاریخ انتشار 2016