Comparative evaluation of lesion detectability for 6 PET imaging platforms using a highly reproducible whole-body phantom with (22)Na lesions and localization ROC analysis.

نویسندگان

  • Dan J Kadrmas
  • Paul E Christian
چکیده

UNLABELLED The lesion detectability performance of 6 PET imaging platforms has been compared using a highly reproducible whole-body phantom and localization receiver operating characteristic (LROC) analysis. METHODS A realistic whole-body phantom consisting of brain, thorax with lungs and liver, and pelvis with bladder was assembled and outfitted with 27 semipermanent (22)Na lesions of various sizes and activity concentrations. The background compartments were reproducibly filled with (18)F solutions. The phantom was imaged under the condition of equal emission scan time on 7 PET platforms: Advance, HR+, HR961, C-PET, IRIX, MCD, and AXIS. Imaging data were processed using manufacturer-supplied software and defaults, and LROC evaluation was performed using 11 human observers. RESULTS Near-nominal counting rates were obtained for the NaI systems, and the bismuth germanate (BGO) systems were operated well below nominal counting rates. The BGO systems provided the highest lesion detection performance, followed by the large-area dedicated NaI system, and hybrid PET gamma cameras. Lesion detectability was highly dependent on lesion size, with all systems exhibiting similar performance for 16-mm lesions but differentiated performance for lesions < or =12 mm. CONCLUSION Reconstruction methodology can have a significant effect on lesion detectability. PET lesion detectability performance is correlated with system cost and imaging characteristics. For a particular imaging task, care should be taken to ensure that the scanner being used is appropriate and that the scan time is adjusted accordingly to ensure good lesion detectability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Importance of defect detectability in Positron Emission Tomography imaging of abdominal lesions

Objective(s): This study was designed to assess defect detectability in positron emission tomography (PET) imaging of abdominal lesions. Methods: A National Electrical Manufactures Association International Electrotechnical Commission phantom was used. The simulated abdominal lesion was scanned for 10 min using dynamic list-mode acquisition method. Images, acquired with scan duration of 1-10 mi...

متن کامل

Interpreting results from a comparative study of lesion detectability for 6 different PET systems.

The article by Kadrmas and Christian (1), which appears in this issue of The Journal of Nuclear Medicine, is a well-written account of a comprehensive study that compares lesion detectability of 6 different commercial PET imaging systems, including 2 state-ofthe-art high-resolution dedicated bismuth germanate (BGO) systems, an older dedicated BGO system, a dedicated NaI(Tl) system, and 3 NaI(Tl...

متن کامل

Evaluation of Simultaneous Dual-radioisotope SPECT Imaging Using 18F-fluorodeoxyglucose and 99mTc-tetrofosmin

Objective(s): Use of a positron emission tomography (PET)/single-photonemission computed tomography (SPECT) system facilitates the simultaneousacquisition of images with fluorine-18 fluorodeoxyglucose (18F-FDG) andtechnetium (99mTc)-tetrofosmin. However, 18F has a short half-life, and 511keV Compton-scattered photons are detected in the 99mTc energy window.Therefore, in this study, we aimed to ...

متن کامل

Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST

Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...

متن کامل

Evaluating image reconstruction methods for tumor detection in 3-dimensional whole-body PET oncology imaging.

UNLABELLED We compare 3 image reconstruction algorithms for use in 3-dimensional (3D) whole-body PET oncology imaging. We have previously shown that combining Fourier rebinning (FORE) with 2-dimensional (2D) statistical image reconstruction via the ordered-subsets expectation-maximization (OSEM) and attenuation-weighted OSEM (AWOSEM) algorithms demonstrates improvements in image signal-to-noise...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 43 11  شماره 

صفحات  -

تاریخ انتشار 2002