Experimental and Monte Carlo simulation studies of open cylindrical radon monitoring device using CR-39 detector.
نویسندگان
چکیده
There are several methods of measuring radon concentrations but nuclear track detector cylindrical dosimeters are widely employed. In this investigation, the consequence of effective volumes of the dosimeters on the registration of alpha tracks in a CR-39 detector was studied. In a series of experiments an optimum radius for a CR-39-based open cylindrical radon dosimeter was found to be about 3 cm. Monte Carlo simulation techniques have been employed to verify the experimental results. In this context, a computer code Monte Carlo simulation dosimetry (MOCSID) was developed. Monte Carlo simulation experiments gave the optimum radius of the dosimeters as 3.0 cm. The experimental results are in good agreement with those obtained by Monte Carlo design calculations. In addition to this, plate-out effects of radon progeny were also studied. It was observed that the contribution of radon progeny (218Po and 214Po) plated-out on the wall of the dosimeters increases with an increase of dosimeter radii and then decrease to 0 at a radius of about 3 cm if a point detector has been installed at the center of the dosimeter base. In the code MOCSID different types of random number generators were employed. The results of this research are very useful for designing an optimum size of radon dosimeters.
منابع مشابه
Calculating CR-39 Response to Radon in Water Using Monte Carlo Simulation
Introduction CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Materials and Methods Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arri...
متن کاملExperimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum
Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...
متن کاملA new model to account for track overlap in CR-39 data
The solid-state nuclear track detector CR-39 is widely used as a detecting mechanism in physics experiments as well as for industrial purposes such as neutron dosimetry and radon detection. The upper limit of detectable charged-particle fluence on CR-39 is set by physical overlapping or ‘pulse pileup’ of particle tracks on the surface. In the low-overlap regime the overlapping fraction of track...
متن کاملA further study of the (CR–LR) difference technique for retrospective radon exposure assessment
The (CR–LR) difference technique, based on the CR-39 and LR 115 detectors, for the determination of implanted Po in glass after deposition of short-lived radon progeny, was analyzed in details in this paper. The sensitivities of both detectors were calculated using the Monte Carlo method with V functions particularly derived in our previous works for the detectors used in the present experiment...
متن کاملInvestigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study
Background: Obtaining high quality images in Single Photon Emission Tomography (SPECT) device  is the most important goal in nuclear medicine. Because if image quality is low, the possibility of making a mistake in diagnosing and treating the patient will rise. Studying effective factors in spatial resolution of imaging systems is thus deemed to be vital. One of the most important factors in S...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of environmental radioactivity
دوره 65 2 شماره
صفحات -
تاریخ انتشار 2003