Long-Term Stability of One-Inch Condenser Microphones Calibrated at the National Institute of Standards and Technology
نویسندگان
چکیده
The devices calibrated most frequently by the acoustical measurement services at the National Institute of Standards and Technology (NIST) over the 50-year period from 1963 to 2012 were one-inch condenser microphones of three specific standard types: LS1Pn, LS1Po, and WS1P. Due to its long history of providing calibrations of such microphones to customers, NIST is in a unique position to analyze data concerning the long-term stability of these devices. This long history has enabled NIST to acquire and aggregate a substantial amount of repeat calibration data for a large number of microphones that belong to various other standards and calibration laboratories. In addition to determining microphone sensitivities at the time of calibration, it is important to have confidence that the microphones do not typically undergo significant drift as compared to the calibration uncertainty during the periods between calibrations. For each of the three microphone types, an average drift rate and approximate 95 % confidence interval were computed by two different statistical methods, and the results from the two methods were found to differ insignificantly in each case. These results apply to typical microphones of these types that are used in a suitable environment and handled with care. The average drift rate for Type LS1Pn microphones was -0.004 dB/year to 0.003 dB/year. The average drift rate for Type LS1Po microphones was -0.016 dB/year to 0.008 dB/year. The average drift rate for Type WS1P microphones was -0.004 dB/year to 0.018 dB/year. For each of these microphone types, the average drift rate is not significantly different from zero. This result is consistent with the performance expected of condenser microphones designed for use as transfer standards. In addition, the values that bound the confidence intervals are well within the limits specified for long-term stability in international standards. Even though these results show very good long-term stability historically for these microphone types, it is expected that periodic calibrations will always be done to track the calibration history of individual microphones and check for anomalies indicative of shifts in sensitivity.
منابع مشابه
Improvement of Efficiency of Coal-Fired Steam Power Plant by Reducing Heat Rejection Temperature at Condenser Using Kalina Cycle
This paper proposes an approach for improving the plant efficiency by reducing the heat rejection temperature of power cycle using Kalina Cycle System 11 (KCS11) which is integrated at the steam condenser of a 500 MWe SubC (subcritical) coal-fired power plant. It is modelled by using power plant simulation software ‘Cycle Tempo’ at different plant operating conditions. Results show t...
متن کاملThe Long Term Calibration Stability of Critical Flow Nozzles and Laminar Flowmeters
The National Institute of Standards and Technology (NIST) has performed calibrations of gas flowmeters using piston and bell provers for three decades. Most of the meters calibrated have been either critical flow nozzles or laminar flowmeters since these meter types are generally chosen as the working standards or transfer standards by other flow calibration laboratories. Often the same meters ...
متن کاملNew Measurement Service for Determining Pressure Sensitivity of Type LS2aP Microphones by the Reciprocity Method
A new National Institute of Standards and Technology (NIST) measurement service has been developed for determining the pressure sensitivities of American National Standards Institute and International Electrotechnical Commission type LS2aP laboratory standard microphones over the frequency range 31.5 Hz to 20 000 Hz. At most frequencies common to the new service and the old service, the values ...
متن کاملStability Study of Iriba Brucellosis Full-dose and Reduced-dose Vaccine Produced by Razi Institute in Iran
Stability study of biological products plays an important role for determination of product changes in maintenance period and ensuring of safety and efficacy of vaccines. In this research, accelerated and long-term stability study performed for six batches of full and reduced-dose cattle Iriba strain brucellosis vaccine that manufactured by Razi vaccine and serum research institute as a new v...
متن کاملAn Investigation of Co-Movement of Financial Stability Index with Macro-Prudential Indicator through Wavelet Analysis
The present study aims at developing an aggregate financial stability index by using banking sector indices to assess financial stability and examine if the variable of credit-to-GDP gap corresponds to its long-term trend which represents the macro-prudential indicator has co-movement with the built financial stability index? To this end, monthly banking balance sheet data were collected from t...
متن کامل