Enhanced corneal compensation for scanning laser polarimetry on eyes with atypical polarisation pattern.

نویسندگان

  • M Tóth
  • G Holló
چکیده

AIM To investigate the potential advantage of an enhanced corneal compensation algorithm (ECC) compared with variable corneal compensation (VCC) in the analysis of scanning laser polarimetric (SLP) images with atypical retardation pattern (ARP). METHODS SLP-VCC images with ARP (typical scan score (TSS) <80) of one eye of each of 27 glaucoma patients and 19 healthy subjects were compared with the corresponding SLP-ECC images obtained at the same session. RESULTS ARP was present in 10.4% of the normals and 15.5% of the glaucoma patients imaged with SLP-VCC over 9 months. In both groups TSS was higher for ECC than for VCC (p<0.001). In glaucoma TSNIT, superior and inferior average thickness values were significantly lower, and TSNIT (measuring ellipse around the optic nerve head in the four (temporal, superior, nasal, inferior) quadrants) standard deviation was significantly higher with ECC than with VCC (p<0.001). In the normal group nerve fibre indicator (NFI) was lower with ECC than with VCC (p=0.007). TSNIT average was smaller and TSNIT standard deviation was higher with ECC (p<0.001). Superior and inferior average thickness did not differ between VCC and ECC in the normal group. CONCLUSIONS The new ECC software substantially improves polarimetric image analysis on eyes showing atypical polarisation pattern.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between Scanning Laser Polarimetry with Enhanced Corneal Compensation and with Variable Corneal Compensation

PURPOSE To evaluate the structure-function relationships between retinal sensitivity measured by Humphrey visual field analyzer (HVFA) and the retinal nerve fiber layer (RNFL) thickness measured by scanning laser polarimetry (SLP) with variable corneal compensation (VCC) and enhanced corneal compensation (ECC) in glaucomatous and healthy eyes. METHODS Fifty-three eyes with an atypical birefri...

متن کامل

Retinal nerve fibre layer assessment in myopic glaucomatous eyes: comparison of GDx variable corneal compensation with GDx enhanced corneal compensation

AIM To compare the results of scanning laser polarimetry (GDx) with variable corneal compensation (VCC) and enhanced corneal compensation (ECC) when applied to myopic glaucomatous eyes. METHODS Forty glaucoma eyes with moderate myopia (between -3 and -6 D) and 35 glaucoma eyes with high myopia (-8 D or greater) were enrolled in this study. GDx VCC, GDx ECC and standard automated perimetry (SA...

متن کامل

Detection of glaucoma using scanning laser polarimetry with enhanced corneal compensation.

PURPOSE To evaluate and compare the diagnostic accuracies for glaucoma detection of scanning laser polarimetry (SLP) with enhanced corneal compensation (GDx ECC) and variable corneal compensation (GDx VCC; both by Carl Zeiss Meditec, Dublin, CA), according to different levels of disease severity and presence of atypical retardation patterns. METHODS The study included 102 eyes of 68 patients ...

متن کامل

Diagnostic accuracy of scanning laser polarimetry with enhanced versus variable corneal compensation.

PURPOSE To compare the diagnostic accuracy of scanning laser polarimetry (SLP) parameters between images taken with enhanced corneal compensation (ECC) and those with variable corneal compensation (VCC) and to explore the effect of atypical birefringence patterns on this accuracy. DESIGN Cross-sectional observational study. PARTICIPANTS Forty-one healthy subjects and 92 patients with primar...

متن کامل

Scanning laser polarimetry with variable and enhanced corneal compensation in normal and glaucomatous eyes.

PURPOSE To investigate whether correction for atypical birefringence pattern (ABP) using scanning laser polarimetry with enhanced corneal compensation (SLP-ECC) reduces the severity of ABP compared with variable corneal compensation (SLP-VCC) and improves the correlation with visual function. DESIGN Prospective observational study. METHODS Normal and glaucomatous eyes enrolled from four cli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 89 9  شماره 

صفحات  -

تاریخ انتشار 2005