Visibility of transparent objects in the eye by retroillumination.

نویسنده

  • N Brown
چکیده

Retroillumination is performed at the slit-lamp with the binocular microscope focused upon the object which is illuminated from behind by the slit-lamp beam reflected off some structure posterior to the object (Vogt, I930). Objects in the cornea and lens are observed in this way and the reflectors used are the iris, the lens, or the fundus. The use of the ophthalmoscope for retroillumination of the cornea is also described (Chandler, I945). Objects are visible because they interfere with the emergent light from the eye by obstruction, refraction, respersion (Berliner, 1943), and reflection. Transparent objects are visible by retroillumination when the refractive index of the object is above or below that of the surrounding medium. The property mainly responsible is refraction, but reflection also plays some part. The observed appearance changes with the direction of the retroillumination and with the refractive nature of the object. From the appearance of an object under varying retroillumination conditions, conclusions can be drawn about the refractive nature of the object. Although a variety of combinations of shapes and refractive indices are possible in the object, these can be resolved into only two observable effects: (i) The object acting as a diverging refractor (lens or cylinder). (2) The object acting as a converging refractor (lens or cylinder). Clinical examples are shown in macrophotographs made by the technique previously described (Brown, I970). Photographs are shown for comparison of a diverging lens (plano-concave) and of a converging lens (plano-convex) (Fig. 2). A model has been constructed to resemble objects found in the eye. The model has two spherical objects imbedded in a clear medium (gelatin): one object of low refractive index (air) which acts as a diverging lens, and one of high refractive index (liquid paraffin) which acts as a converging lens. Photographs are shown of the model under varying conditions of illumination (Figs 3, 4, and 5).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of the daily minimum visibility meteorological conditions using RVR data at IKA airport during 2013-2014

 Investigation of the daily minimum visibility meteorological conditions using RVR data at IKA airport during 2013-2014 Hatami, J. 1, Sabetghadam, S. 2*, Ahmadi-Givi, F. 3 1M.Sc. Student, Institute of Geophysics, University of Tehran 2Assistant Professor, Institute of Geophysics, University of Tehran 3Associate Professor, Institute of Geophysics, University of Tehran   Abstract Atmospher...

متن کامل

بررسی تأثیر کاربرد پانسمان فیلم شفاف بر میزان عوارض محل ورود کتتر در بیماران تحت آنژیوگرافی عروق کرونر

Introduction: Bleeding, hematoma and cyanosis in the arterial catheter site are considered the most important complications after coronary artery angiography. A method in which homeostasis can result faster and patient can walk sooner should be found. Therefore, this study aimed to compare two methods of sandbags and transparent film dressings to reduce complications after coronary artery angio...

متن کامل

Longitudinal study of posterior subcapsular opacities using the National Eye Institute computer planimetry system.

BACKGROUND The National Eye Institute (NEI) computer planimetry system has proved to be helpful in cross sectional studies by providing clinically useful area measurements of posterior subcapsular cataracts (PSC) and other opacities from retroillumination photographs. In this study, we evaluated the worth of this system in detecting PSC area changes over time. METHODS Using the Neitz-Kawara c...

متن کامل

Retroillumination versus reflected-light images in the photographic assessment of posterior capsule opacification.

PURPOSE To investigate the relative merit of retroillumination and of reflected light slit-lamp-derived photographs in the assessment of the opacification of the posterior lens capsule. METHODS Retroillumination and slit-lamp-derived reflected-light photographs were taken on 23 consecutive eyes with posterior capsule opacification (PCO) in uncomplicated pseudophakia. Subjective grading was pe...

متن کامل

Binary Space Parititions in Plücker Space

One of the important potential applications of computational geometry is in the field of computer graphics. One challenging computational problem in computer graphics is that of rendering scenes with nearly photographic realism. A major distinction in lighting and shading models in computer graphics is between local illumination models and global illumination models. Local illumination models a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 55 8  شماره 

صفحات  -

تاریخ انتشار 1971