Automated Clean-up of PCB extracts from Waste Oil using the Agilent 7696A Sample Prep WorkBench

نویسندگان

  • Karine Jacq
  • Peter Mrozinski
چکیده

Solid waste, including petroleum based waste oils, transformer oil or mineral oil are screened for the presence of polychlorinated biphenyls (PCBs). The analysis is typically performed by GC-ECD or GC-MS after clean-up using column chromatography, solid phase extraction (SPE), or dispersive solid phase extraction (d-SPE). Clean-up on silica or acidified silica removes polar constituents that can interfere with the PCB analytes and/or contaminate the analytical system. A miniaturized dispersive SPE method using SiOH/H2SO4 adsorbent was automated on the Agilent 7696A Sample Prep WorkBench system. The extracts could be purified efficiently and reproducible. In combination with GC-ECD, GC-MS or GC-MS/MS, also applying back-flushing, an automated, accurate and robust determination of PCBs in waste oils is possible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated Clean-up for Mineral Oil (Hydrocarbon Oil Index) Analysis using the Agilent 7696A Sample Prep WorkBench

Mineral oil (or Hydrocarbon oil) in water samples is determined by liquid-liquid extraction, followed by a clean-up step on Florisil, and GC-FID analysis. Using the Agilent 7696A Sample Prep WorkBench system, drying and clean-up of samples obtained after liquid-liquid extraction can be automated. High recoveries and excellent reproducibility are obtained for the mineral oil fraction, while the ...

متن کامل

Automated Sample Preparation for FAME Analysis in Edible Oils Using an Agilent 7696A Sample Prep WorkBench

Automating fatty acid derivatization and preparation of calibration standards on an Agilent 7696A Sample Prep WorkBench for fatty acid methyl esters (FAME) analysis can provide comparable precision, better recoveries, and more accurate calibration compared to manual procedures. Hands-on time, reagent usage, and exposure to hazardous chemicals are all greatly reduced. This automated approach has...

متن کامل

Improving the Analysis of Fatty Acid Methyl Esters Using Automated Sample Preparation Techniques

An automated method for esterifying fatty acids in canola oil samples is presented. Using the Agilent 7696A Sample Prep WorkBench, a side-by-side comparison was undertaken comparing a manual method employing automatic pipettors to a method developed for this automated system. Using the Agilent 7696A Sample Prep WorkBench, preparation of 10 samples resulted in 3% RSD for both an acid-catalyzed a...

متن کامل

Analysis of bisphenol A leaching from baby feeding bottles

Bisphenol A can leach out from the plastic surfaces of food containers and has been detected in various matrices such as plasma, urine and groundwater. Bipshenol A is an endocrine disruptor, which can mimic the body’s own hormones such as estrogen and may lead to negative health effects. In this Application Note, we describe a method to quantify bisphenol A and a structurally similar analog bis...

متن کامل

An improved clean-up strategy for simultaneous analysis of polychlorinated dibenzo-p-dioxins (PCDD), polychlorinated dibenzofurans (PCDF), and polychlorinated biphenyls (PCB) in fatty food samples.

The study and extension of a simple automated clean-up method for polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) to a broad range of polychlorinated biphenyls (PCB) is described. The isolation of seven PCDD, ten PCDF, and three coplanar PCB (cPCB) is extended to eight monoortho substituted PCB and seven so-called "marker PCB" (Aroclor 1260) for fatty food samp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011