Initial Clinical Experience with the Endologix AFX Unibody Stent Graft System for Treating Patients with Abdominal Aortic Aneurysms: A Case Controlled Comparative Study

نویسندگان

  • George N. Kouvelos
  • Petroula Nana
  • Vasilios Bouris
  • Michalis Peroulis
  • Aikaterini Drakou
  • Nikolaos Rousas
  • Athanasios Giannoukas
  • Miltiadis I. Matsagkas
چکیده

PURPOSE The newly designed unibody AFX endograft system for endovascular aortic aneurysm repair is the only graft with anatomical fixation to the aortic bifurcation in comparison to most other grafts that use the infrarenal neck as the main fixation point. The aim of this study was to assess the preliminary results of the AFX stent-graft system used with infrarenal aortic component and compare them with those obtained in patients treated with a well established endograft of the same material and pure infrarenal fixation as the Gore Excluder. MATERIALS AND METHODS A retrospective analysis of prospectively collected data from March 2014 to December 2014 identified 10 elective abdominal aortic aneurysm patients treated with the AFX endograft, in comparison to a matched group of 20 patients treated with the Excluder stent-graft. Endpoints included technical and clinical success, freedom from any secondary intervention, any type of endoleak and aneurysm related death. RESULTS Primary technical success was achieved in all patients and no 30-day device related complications or deaths were occurred. The two groups were similar in terms of radiation burden, contrast media, duration of the procedure, post implantation syndrome and in-hospital stay. During a median follow-up period of 23 months (range, 18-26 months) there were no differences in clinical success, freedom from reintervention and aneurysm related death. No type I endoleak was observed in either group. Five of the 6 type II endoleaks (1 in the AFX and 4 in the Excluder group) spontaneously resolved, while in only one patient (Excluder) the endoleak remained without however any change in aneurysm sac diameter (log rank=0.34). CONCLUSION The initial experience with the AFX stent graft system is promising, with successful aneurysm exclusion and good short-term results. Further and larger studies are needed to fully evaluate the sort as well as the long-term results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Initial experience with a new fenestrated stent graft.

OBJECTIVES The Anaconda fenestrated stent graft (Vascutek, Inchinnan, United Kingdom) is a new device that can easily be repositioned during deployment. This study evaluated its feasibility for treating abdominal aortic aneurysms with inadequate infrarenal sealing zones. METHODS Patients undergoing stent graft placement at two institutions in the United Kingdom were recruited. RESULTS A tot...

متن کامل

12-year Experience with the Endologix Powerlink Device in Endovascular Repair of Abdominal Aortic Aneurysms

Since Parodi reported the first successful endovascular aneurysm repair procedure in 1991, this procedure has gained wide acceptance for the treatment of abdominal aortic aneurysms in the past two decades. This minimally invasive approach has been proven effective and safe in the treatment of abdominal aortic aneurysm patients with lower early morbidity and mortality rates compared to open surg...

متن کامل

Aortic arch reconstruction by transluminally placed endovascular branched stent graft.

BACKGROUND Recently, thoracic aortic stent grafting has emerged as an alternative therapeutic modality for patients with thoracic aortic aneurysms and aortic dissections. However, its application has been limited to descending thoracic aortic aneurysms distal to the aortic arch. We report our initial clinical experience of endovascular branched stent graft repair for aortic arch aneurysms. ME...

متن کامل

Ventana fenestrated stent-graft system for endovascular repair of juxtarenal aortic aneurysms.

PURPOSE To describe the initial use of an off-the-shelf fenestrated stent-graft system for endovascular repair of juxtarenal abdominal aortic aneurysms. TECHNIQUE The off-the-shelf Ventana fenestrated stent-graft system consists of a 25-mm IntuiTrak self-expanding bifurcated stent-graft implanted at the aortic bifurcation. A Ventana self-expanding fenestrated proximal extension stent-graft is...

متن کامل

Acquired Infrarenal Abdominal Aortic Coarctation: Treatment with Percutaneous Self Expandable Stent

Abdominal aortic coarctation is an extremely rare vascular pathology. Its etiology can be congenital or acquired. Here we present a case of acquired infrarenal abdominal coarctation in a 66-year-old woman who complained of low back and legs pain. She had no signs of resting lower limb ischemia, with diminished distal pulses and normal blood pressure in upper and lower extremities. Magnetic reso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2017