A novel CT acquisition and analysis technique for breathing motion modeling.

نویسندگان

  • Daniel A Low
  • Benjamin M White
  • Percy P Lee
  • David H Thomas
  • Sergio Gaudio
  • Shyam S Jani
  • Xiao Wu
  • James M Lamb
چکیده

To report on a novel technique for providing artifact-free quantitative four-dimensional computed tomography (4DCT) image datasets for breathing motion modeling. Commercial clinical 4DCT methods have difficulty managing irregular breathing. The resulting images contain motion-induced artifacts that can distort structures and inaccurately characterize breathing motion. We have developed a novel scanning and analysis method for motion-correlated CT that utilizes standard repeated fast helical acquisitions, a simultaneous breathing surrogate measurement, deformable image registration, and a published breathing motion model. The motion model differs from the CT-measured motion by an average of 0.65 mm, indicating the precision of the motion model. The integral of the divergence of one of the motion model parameters is predicted to be a constant 1.11 and is found in this case to be 1.09, indicating the accuracy of the motion model. The proposed technique shows promise for providing motion-artifact free images at user-selected breathing phases, accurate Hounsfield units, and noise characteristics similar to non-4D CT techniques, at a patient dose similar to or less than current 4DCT techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Construction of a Seismometer Based on the Moiré Technique: Detailed Theoretical Analysis, Experimental Apparatus, and Primary Results

We have built a vertical seismometer that works based on the moiré technique. One grating is attached to the suspended mass and one to the frame of the instrument. The two gratings are in relative motion, and the resulting moiré pattern magnifies this motion. The intensity of a light beam passing through the moving moiré fringes changes with time, and a light detecting syst...

متن کامل

Management of respiratory motion in PET/computed tomography: the state of the art

Combined PET/computed tomography (CT) is of value in cancer diagnosis, follow-up, and treatment planning. For cancers located in the thorax or abdomen, the patient's breathing causes artifacts and errors in PET and CT images. Many different approaches for artifact avoidance or correction have been developed; most are based on gated acquisition and synchronization between the respiratory signal ...

متن کامل

Tumor tracking method based on a deformable 4D CT breathing motion model driven by an external surface surrogate.

PURPOSE To develop a tumor tracking method based on a surrogate-driven motion model, which provides noninvasive dynamic localization of extracranial targets for the compensation of respiration-induced intrafraction motion in high-precision radiation therapy. METHODS AND MATERIALS The proposed approach is based on a patient-specific breathing motion model, derived a priori from 4-dimensional p...

متن کامل

Analysis of Heart Rate Variability During Meditative and Non-Meditative State Using Analysis of Variance

In this paper the main objective is to quantify and compare the instantaneous value of heart rate for normal breathing patterns during Meditation and Non Meditation conditions. This paper involves Analysis of Variance (ANOVA) technique for the analysis of the heart rate variability patterns during the meditative and non meditative states. The analysis is divided into three stages i.e. data acqu...

متن کامل

Prospective respiratory-gated micro-CT of free breathing rodents.

Microcomputed tomography (Micro-CT) has the potential to noninvasively image the structure of organs in rodent models with high spatial resolution and relatively short image acquisition times. However, motion artifacts associated with the normal respiratory motion of the animal may arise when imaging the abdomen or thorax. To reduce these artifacts and the accompanying loss of spatial resolutio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 58 11  شماره 

صفحات  -

تاریخ انتشار 2013