Analysis of Failures in the Power Grid via the Pseudo-inverse of the Admittance Matrix

نویسندگان

  • Saleh Soltan
  • Gil Zussman
چکیده

Recent large-scale power outages demonstrated the limitations of percolationand epidemic-based tools in modeling failures in power grids. Hence, we study the impact of line failures on the flow changes and cascade in the transmission system of the power grid by using a linearized power flow model. We use the pseudo-inverse of the power grid admittance matrix to obtain upper bounds on the flow changes after a failure, develop an efficient algorithm to identify the cascading failure evolution, and develop a simple heuristic to find a set of line failures with the highest impact. Overall, the results demonstrate that the resistance distance and the pseudo-inverse of admittance matrix provide important insights and can support the development of efficient algorithms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Procedure for Determining Current Harmonic Contribution around an Operation Point at PCC Using Load Modelling Based on Crossed Frequency Admittance Matrix

Abstract:Today, one of the important issues of power quality (PQ) in power systems is the current harmonics. Increasing expansion of nonlinear loads at different parts of the electric network makes harmonic distortion flow through the network. This causes the network to have background voltage and current harmonic distortion and even affect on the PQ of linear load performance. Therefore, it is...

متن کامل

Flexible Power Electronic Transformer for Power Flow Control Applications

This paper proposes a Flexible Power Electronic Transformer (FPET) for the application in the micro-grids. The low frequency transformer is usually used at the Point of Common Coupling (PCC) to connect the low voltage grid and utility network to each other. The conventional 50Hz transformer results in enhanced low voltage-grid power management system during grid-connected operation. In this pap...

متن کامل

On the Properties of the Compound Nodal Admittance Matrix of Polyphase Power Systems

Most techniques for power system analysis model the grid by exact electrical circuits. For instance, in power flow study, state estimation, and voltage stability assessment, the use of admittance parameters (i.e., the nodal admittance matrix) and hybrid parameters is common. Moreover, network reduction techniques (e.g., Kron reduction) are often applied to decrease the size of large grid models...

متن کامل

A New DPC-SVM for Matrix Converter Used in Wind Energy Conversion System Based on Multiphase Permanent Magnet Synchronous Generator

This paper proposes a novel wind energy conversion system based on a Five-phase Permanent Magnetic Synchronous Generator (5-PMSG) and a Five to three Matrix Converter (5-3MC). The low cost and volume and also eliminating grid side converter controller are attractive aspects of the proposed topology compared to the conventional with back-to-back converters. The control of active and reactive pow...

متن کامل

Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes

A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inver...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014