A Multi-echo Acquisition Method with Reduced Echo Spacing for Robust IDEAL Water-Fat Decomposition at 3T

نویسندگان

  • H. Yu
  • A. Shimakawa
  • C. A. McKenzie
  • A. T. Vu
  • A. C. Brau
  • P. J. Beatty
  • S. B. Reeder
  • J. H. Brittain
چکیده

images from 6-pt IDEAL reconstruction, and the R2* map (c) from 6-pt T2*-IDEAL reconstruction. The echo spacing was 1.3ms (1.1π). Uniform water-fat decomposition was achieved. Figure 1 (left): IDEAL cost functions for two sets of echo times. The purpose of the IDEAL iteration is to search for the minimum (0Hz in this example) of the cost function curves. To avoid converging to local minima, the initial guess needs to be within the marked tolerance zone. In general, a shorter echo spacing is associated with a bigger tolerance zone, thus offering more reliable decomposition.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac Imaging with Chemical Shift Based Water-Fat Separation at 3T

Introduction Chemical shift based water-fat separation techniques have been demonstrated for 1.5T cardiac imaging of several pathologies, including fatty infiltration of chronic infarction; arrhythmogenic right ventricular cardiomyopathy (ARVC); fatty tumors; and conditions such as myocarditis and pericarditis [1-4]. Higher field strengths (3T) are now often used in cardiac MRI due to improved ...

متن کامل

3T Coronary MRA using 3D Multi-interleaved Multi-echo Acquisition and VARPRO Fat-water Separation

Introduction: Coronary MR Angiography is a valuable tool for non-invasive assessment of coronary arteries. Presently, contrastenhanced, fat-saturated, ECG-triggered and navigator-gated 3D spoiled gradient-echo sequence is employed for whole-heart Coronary MRA at 3T. However, large static field variations at 3T frequently result in non-uniform fat-suppression over the field-of-view (FOV), obscur...

متن کامل

IDEAL at 7T in Mice Using Asymmetric Spin Echo and Gradient Echo Acquisitions

An asymmetric spin echo (aSE) technique was developed to produce uniform, robust fat-water separation in mice at 7T using Iterative Decomposition of Water and Fat with Echo Asymmetry and Least-squares estimation method (IDEAL). The aSE technique had superior image quality as compared to gradient echo IDEAL estimation. Both the spin echo and gradient echo IDEAL techniques resulted in more accura...

متن کامل

Preliminary results of IDEAL fat/water separation at 9.4T

Introduction An iterative Dixon algorithm (IDEAL) [1] was established for efficient fat/water-separation during the last years. Here the method was executed invivo on a dead rat on 9.4T in order to verify the high-field performance of IDEAL. Data were acquired with a vendor supplied 3D multigradientecho sequence. Method Experiments were performed on a 9.4T Bruker Biospec 94/20 small animal scan...

متن کامل

Ovarian masses: MR imaging with T1-weighted 3-dimensional gradient-echo IDEAL water-fat separation sequence at 3T.

PURPOSE We retrospectively compared the efficacy of 3-dimensional (3D) gradient-echo magnetic resonance T(1)-weighted sequence using the iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) technique with the efficacy of conventional 3D gradient-echo sequences for diagnosing ovarian masses at 3T. MATERIALS AND METHODS In images of 32 women (mean ag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007