Stability indicating HPLC-UV method for determination of dapoxetine HCl in pharmaceutical product.

نویسندگان

  • Kai Bin Liew
  • Kok Khiang Peh
چکیده

A stability-indicating HPLC-UV method for the determination of dapoxetine hydrochloride in solution and pharmaceutical product was developed. The mobile phase was composed of acetonitrile and 0.2 M ammonium acetate buffer at 50 : 50 ratio. The chromatographic parameters, theoretical plates (N), tailing factor (T), capacity factor (k') and peak asymmetry factor (As) were calculated. Stress degradation studies, namely, acid, alkali, oxidation, heat and UV light, were performed. The analyte was eluted at 5.8 min using gradient system at a flow rate of 1.5 mL/min. The theoretical plates count was > 2000, tailing factor < 1.54, capacity factor > 5.38 and peak asymmetry factor was < 1.10. The method was linear from 1 to 40 microg/mL with a correlation coefficient of 0.9994. The intraday precision and accuracy values were 0.14-1.54% and 0.63-1.83%, respectively. On the other hand, the interday precision and accuracy results were 0.49-1.83% and 1.15-1.85%, respectively. The drug solution was stable at ambient room temperature (26 degrees C) for 48 h. Dapoxetine HCI was found susceptible to oxidation and degraded slightly under acid and alkali conditions but was stable under UV light and heat. No interference from tablet excipiets and degradation products was found. Hence, the method can be employed as a stability-indicating method for the determination of dapoxetine HCl in pharmaceutical products.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms

Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...

متن کامل

A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms

Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...

متن کامل

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method

This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...

متن کامل

Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method

This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta poloniae pharmaceutica

دوره 71 3  شماره 

صفحات  -

تاریخ انتشار 2014