Endobronchial ultrasonography using a guide sheath increases the ability to diagnose peripheral pulmonary lesions endoscopically.
نویسندگان
چکیده
STUDY OBJECTIVE To assess the ability of endobronchial ultrasonography (EBUS) using a guide sheath (EBUS-GS) to diagnose peripheral pulmonary lesions. METHOD We devised a technique for EBUS-GS covering a miniature probe, and 150 lesions were evaluated in a prospective open study. In this procedure, the probe covered by a guide sheath is introduced into the lesion via the working channel of a bronchoscope. The probe is withdrawn, while the guide sheath is left in situ. A brush or biopsy forceps is introduced through the guide sheath into the lesion. RESULTS One hundred sixteen of 150 EBUS-GS procedures (77%) were diagnostic. Cases in which the probe was located within the lesion had a significantly higher diagnostic yield (105 of 121 cases, 87%) than when the probe was located adjacent to it (8 of 19 cases, 42%) [p < 0.0001, chi(2)]. The diagnostic yield from EBUS-GS in lesions 10 to 15 to 20 to </= 30 mm (33 of 43 lesions, 77%; p = 0.96, chi(2)) were similar, demonstrating the efficacy of EBUS-GS even in lesions </= 10 mm in diameter. In 54 of 81 lesions </= 20 mm, fluoroscopy was not able to confirm whether the forceps reached the lesion. However, the yield was the same with (67%, 18 of 27 lesions) and without (74%, 40 of 54 lesions) successful fluoroscopy (p = 0.96, chi(2)). Moderate bleeding occurred in two patients (1%); there were no other complications. CONCLUSIONS EBUS-GS is a useful method for collecting samples from peripheral pulmonary lesions, even those too small to be visualized under fluoroscopy.
منابع مشابه
Transbronchial needle aspiration through a guide sheath with endobronchial ultrasonography (GS-TBNA) for peripheral pulmonary lesions.
PURPOSE Although, endobronchial ultrasonography with a guide sheath is becoming a common procedure for the diagnosis of peripheral pulmonary lesions, there remain to be some inaccuracies in cases wherein the probe is located outside the lesion. We tested whether adding transbronchial needle aspiration through a guide sheath to the conventional technique increases efficacy for diagnosing periphe...
متن کاملEndobronchial ultrasonography with guide-sheath for peripheral pulmonary lesions.
The usefulness of endobronchial ultrasonography (EBUS) with guide-sheath (GS) as a guide for transbronchial biopsy (TBB) for diagnosing peripheral pulmonary lesions (PPL)s and for improving diagnostic accuracy was evaluated in this study. EBUS-GS-guided TBB was performed in 24 patients with 24 PPLs of < or =30 mm in diameter (average diameter=18.4 mm). A 20-MHz radial-type ultrasound probe, cov...
متن کاملTransbronchial biopsy using endobronchial ultrasonography with a guide sheath and virtual bronchoscopic navigation.
STUDY OBJECTIVES We evaluated the feasibility, safety, and efficacy of transbronchial biopsy (TBB) using endobronchial ultrasonography with a guide sheath (EBUS-GS) and virtual bronchoscopy (VB) navigation for small peripheral pulmonary lesions < or = 30 mm in diameter. DESIGN Pilot study. SETTING A national university hospital. PATIENTS We performed TBB using EBUS-GS with VB navigation f...
متن کاملVirtual bronchoscopic navigation combined with endobronchial ultrasound to diagnose small peripheral pulmonary lesions: a randomised trial
BACKGROUND Bronchoscopy using endobronchial ultrasound (EBUS) can help to diagnose small peripheral pulmonary lesions. However, although biopsy sites can be confirmed, a bronchoscope cannot be guided in EBUS. Virtual bronchoscopic navigation (VBN) can guide a bronchoscope with virtual images, but its value has not been confirmed. METHODS This prospective multicentre study examines the value o...
متن کاملA new middle-range diameter bronchoscope with large channel for transbronchial sampling of peripheral pulmonary lesions.
OBJECTIVE Although the diagnostic yield of guided bronchoscopy for peripheral pulmonary lesions has improved to 70%, it is still low compared with transthoracic needle aspiration. We produced a new bronchoscope with middle-range diameter and large channel (BF-Y0053, Olympus, Japan), and evaluated its diagnostic efficacy for peripheral pulmonary lesions. METHODS This was a retrospective study ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 126 3 شماره
صفحات -
تاریخ انتشار 2004