Real-time and integrated measurement of potential human exposure to particle-bound polycyclic aromatic hydrocarbons (PAHs) from aircraft exhaust.

نویسندگان

  • J W Childers
  • C L Witherspoon
  • L B Smith
  • J D Pleil
چکیده

We used real-time monitors and low-volume air samplers to measure the potential human exposure to airborne polycyclic aromatic hydrocarbon (PAH) concentrations during various flight-related and ground-support activities of C-130H aircraft at an Air National Guard base. We used three types of photoelectric aerosol sensors (PASs) to measure real-time concentrations of particle-bound PAHs in a break room, downwind from a C-130H aircraft during a four-engine run-up test, in a maintenance hangar, in a C-130H aircraft cargo bay during cargo-drop training, downwind from aerospace ground equipment (AGE), and in a C-130H aircraft cargo bay during engine running on/off (ERO) loading and backup exercises. Two low-volume air samplers were collocated with the real-time monitors for all monitoring events except those in the break room and during in-flight activities. Total PAH concentrations in the integrated-air samples followed a general trend: downwind from two AGE units > ERO-loading exercise > four-engine run-up test > maintenance hangar during taxi and takeoff > background measurements in maintenance hangar. Each PAH profile was dominated by naphthalene, the alkyl-substituted naphthalenes, and other PAHs expected to be in the vapor phase. We also found particle-bound PAHs, such as fluoranthene, pyrene, and benzo[a]pyrene in some of the sample extracts. During flight-related exercises, total PAH concentrations in the integrated-air samples were 10-25 times higher than those commonly found in ambient air. Real-time monitor mean responses generally followed the integrated-air sample trends. These monitors provided a semiquantitative temporal profile of ambient PAH concentrations and showed that PAH concentrations can fluctuate rapidly from a baseline level < 20 to > 4,000 ng/m(3) during flight-related activities. Small handheld models of the PAS monitors exhibited potential for assessing incidental personal exposure to particle-bound PAHs in engine exhaust and for serving as a real-time dosimeter to indicate when respiratory protection is advisable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time measurements of jet aircraft engine exhaust.

Particulate-phase exhaust properties from two different types of ground-based jet aircraft engines--high-thrust and turboshaft--were studied with real-time instruments on a portable pallet and additional time-integrated sampling devices. The real-time instruments successfully characterized rapidly changing particulate mass, light absorption, and polycyclic aromatic hydrocarbon (PAH) content. Th...

متن کامل

Occupational exposure to polycyclic aromatic hydrocarbons during Diesel combustion.

Identification and determination of polycyclic aromatic hydrocarbons (PAHs) in Diesel exhaust in the working environment and assessment of workers' occupational exposure to these suspected human carcinogens were the aim of this experimental investigation. The range of exposure factors calculated on the basis of 9 individual PAH concentrations determined in personal air samples shows that time-a...

متن کامل

The potential of low temperature extraction method for analysis of polycyclic aromatic hydrocarbons in refined olive and refined pomace olive oils by HPLC/FLD

Background and Objectives: A method was developed and validated for determining 15 polycyclic aromatic hydrocarbons (PAHs) in refined olive and refined pomace olive oils using high performance liquid chromatography coupled with a fluorescence detector. Materials and Methods: The sample preparation involved liquid–liquid extraction with organic solvent and low temperature clean-up. The low temp...

متن کامل

Risk Assessment of Polycyclic Aromatic Hydrocarbons in Pasta Products Consumed in Nigeria

Background: The present study aimed to quantitatively determine polycyclic aromatic hydrocarbons in pastas consumed in Nigeria with the view of estimating the daily intake amount and the possible risks to consumers. Methods: Sixteen polycyclic aromatic hydrocarbons (PAHs) were determined in locally produced and imported pasta using a GC-Mass Spectrometer. Estimation of daily intake was done on...

متن کامل

Determination of Polycyclic Aromatic Hydrocarbons in Olive and Refined Pomace Olive Oils using HPLC/FLD

ABSTRACT: In this study, an analytical method is developed to determine 15 polycyclic aromatic hydrocarbons (PAHs) in olive and refined pomace olive oils using HPLC coupled with a fluorescence detector. The standardised method of ultrasound-assisted solvent extraction consisted of liquid–liquid extraction with organic solvent and purification on C18 and Florisil bonded-phase cartridges was modi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental Health Perspectives

دوره 108  شماره 

صفحات  -

تاریخ انتشار 2000