Validation of the RightLevelpHTM Detector for Monitoring Gastric pH Running Title: Gastric pH Monitoring
نویسندگان
چکیده
Background: The RightLevelpHTM indicator is a new device designed to measure pH of gastric aspirate obtained via nasogastric tube while minimizing exposure of the operator. Study Objectives: In vivo and in vitro validation of the RightLevelpHTM indicator. Methods: Patients (23) undergoing general anesthesia had placement of a nasogastric tube and gastric pH electrode catheter following endotracheal intubation. Direct intragastric pH was recorded simultaneously with gastric aspirate pH using the RightSpotpHTM indicator as well as an external pH electrode. Measurements were made every 30 minutes until removal of the nasogastric tube as indicated clinically. In vitro validation of the RightLevelpHTM indicator was performed using standard buffer solutions. Results: The pH of clear buffer solutions was linearly related to pH determined by the RightLevelpHTM indicator (R=0.99, P≤0.0001). The pH of gastric aspirate determined by external pH electrode was linearly related to the gastric aspirate pH determined by the RightLevelpHTM indicator (R=0.92, P≤0.0001). Intragastric pH determined by catheter electrode was also linearly related but more loosely correlated to gastric aspirate pH determined by external pH electrode (R=0.52, P≤0.0001) and by the RightLevelpHTM indicator (R=0.56, P≤0.0001). Conclusions: The RightLevelpHTM indicator provides accurate determination of gastric aspirate pH in patients. INTRODUCTION Monitoring gastric pH may be useful in preventing stress ulceration and gastrointestinal bleeding, especially in intensive care unit patients. Determination of gastric pH, in this setting, may be done using an intragastric catheter pH electrode or measuring gastric aspirate pH, either by electrode or indicator paper. The RightLevelpHTM detector is a new device that attaches to a standard nasogastric tube for measurement of aspirate pH using indicator paper technology while minimizing potential exposure to body fluids (Figure 1). The present study compares pH measurements obtained by intragastric catheter pH electrode to that of gastric aspirate determined by external pH electrode and the RightLevelpHTM detector in patients. METHODS The Florida Hospital Tampa Institutional Review Board approved this study that was conducted from January to July of 2012. All patients were 21 years of age or older and had a planned elective procedure requiring general anesthesia with endotracheal intubation and placement of a nasogastric tube. A standard nasogastric tube was secured by suture to a pH electrode catheter (VersaflexTM) and introduced orally by the attending anesthesiologist following endotracheal intubation. Prior to introduction, the pH catheter was calibrated using buffer solutions per the manufacturers direction. Auscultation was also routinely done following tube placement as standard practice. Following placement, gastric aspirate was withdrawn using a standard syringe attached to the RightLevelpHTM indicator and a simultaneous reading of direct intragastric pH was taken from the electrode catheter. If enough gastric aspirate was present, pH was also measured with a laboratory pH electrode. Patients were excluded who had grossly bloody nasogastric aspirate. All operators were previously tested for color blindness (Ishihara). Measurements were then repeated at 30 minute intervals until the nasogastric tube was removed. Results were analyzed comparing direct intragastric pH versus the RightLevelpHTM indicator reading and external laboratory pH electrode measurement using linear regression. Similarly, the RightLevelpHTM indicator reading was compared to the determination of aspirate pH by the external laboratory pH electrode. An in vitro validation study was done using standard clear buffer solutions of pH 2-7. A total of 46 measurements were made in blinded fashion using the RightLevelpHTM indicator and data were analyzed in the same manner as for the in vivo comparisons. Values for pH from electrodes were recorded to 0.01 unit while values for pH by RightLevelpHTM indicator were recorded as 1, 2, 3, 4, 5 or ≥6. RESULTS A total of 23 patients were enrolled in the study. Data were collected from 17, the others having no gastric aspirate (4) or grossly bloody aspirate (2). No complications occurred during the study. Results for the in vitro validation revealed a significant linear relationship between RightLevelpHTM indicator determinations (N=83) and actual pH of clear buffer solutions (P≤0.0001) where RightLevelpHTM= 1.01(Actual pH)-0.02 with R=0.99. The relationship between the pH of 120 gastric aspirate samples determined by external pH electrode and the RightLevelpHTM indicator is illustrated in figure 2. A highly significant linear relationship is seen between the two methods validating pH determination of gastric aspirate by the RightLevelpHTM indicator when compared to a standard laboratory pH electrode. Figure 3 illustrates the relationship between intragastric pH determined by catheter electrode with gastric aspirate pH determined by the RightLevelpHTM indicator. Figure 4 illustrates the relationship between intragastric pH determined by catheter electrode with gastric aspirate pH determined by the external pH electrode. Although significant linear relationships are observed between both external methods for gastric aspirate pH determination, there is significant variability between direct intragastric pH determined by catheter electrode and both external determination methods. DISCUSSION Determination of gastric aspirate pH has been of interest primarily in the context of stress ulcer prophylaxis(1, 2) and nasogastric tube placement(3-5). Methods for determining the pH of gastric aspirate have most commonly utilized either indicator paper or a pH electrode while direct intragastric pH measurement has utilized catheter or capsule based measurement technology(6-21). Use of pH indicator paper or a pH electrode at the bedside requires aspiration of gastric contents and subsequent handling of the sample to directly touch the indicator paper or pH electrode. After measurement, disposal of the sample and associated hardware as well as cleaning and storage of the pH electrode and meter are required. The RightLevelpHTM was designed to offer a quick, inexpensive solution for determination of gastric pH obviating the need for complicated electrode based pH measurement equipment concerns and avoiding contact with gastric aspirate. The current study validates the RightLevelpHTM system in vitro using buffers and for determination of gastric aspirate pH by comparison to simultaneous pH electrode measurement on the same samples. In addition, the RightLevelpHTM system correlates with direct measurement of intragastric pH by catheter electrode similarly to external electrode measurement of gastric aspirate. The RightLevelpHTM indicator offers accurate determination of gastric aspirate pH equivalent to that of pH electrode determinations in
منابع مشابه
Validation of the RightLevelpH Detector for Monitoring Gastric pH.
BACKGROUND The RightLevelpH indicator is a new device designed to measure the pH of gastric aspirate obtained via a nasogastric tube while minimizing exposure of the operator. OBJECTIVE To validate the RightLevelpH indicator in vivo and in vitro. METHODS With general anesthesia, 20 patients had placement of a nasogastric tube and a gastric pH electrode catheter after endotracheal intubation...
متن کاملPostprandial acid reflux is reduced by delayed gastric emptying.
The aim of this study was to investigate influence of delayed gastric emptying on postprandial reflux in esophageal pH. Sixty-nine consecutive patients underwent 24 hour (h) esophageal pH monitoring and gastric emptying. In 24 h esophageal pH monitoring, % postprandial reflux pH<4 for 2 h after each meal (% PRT) was extracted from the 24 h pH profile. After solid test meal (1 mCi, Tc99m) was gi...
متن کاملDual pH probe monitoring versus single pH probe monitoring in infants on milk feeds: the impact on diagnosis.
OBJECTIVES Oesophageal pH monitoring is the gold standard technique for the detection of gastro-oesophageal reflux in adults and children. A standard parameter used to define "abnormal" reflux is the percentage of recording time for which the gastric pH is < 4. This study investigated the relevance of this measure in infants on regular milk feeds whose gastric contents and refluxate will be neu...
متن کاملMagnitude and duration of elevated gastric pH in patients infected with human immunodeficiency virus after administration of chewable, dispersible, buffered didanosine tablets.
STUDY OBJECTIVES To test the hypothesis that gastric pH would be elevated above pH 3.0 for at least 2 hours after administration of chewable, dispersible, buffered didanosine tablets. Doses tested were 200 mg (two 100-mg tablets) and 400 mg (two 200-mg tablets). We also sought to compare these doses with regard to maximum gastric pH (pHmax), time to pHmax (TpH-max), time that gastric pH exceeds...
متن کاملNon-invasive detection of gastro-oesophageal reflux using an ambulatory system.
The aim of this study was the separate measurement of reflux of food and acid into the oesophagus in 37 healthy, ambulant subjects. This was performed by radiolabelling the food and monitoring its reflux with a small directional gamma detector, which was placed externally over the oesophagus, and connected to an ambulatory data recorder. The pH was measured with a conventional oesophageal pH el...
متن کامل