Estimation of total attenuation and scatterer size from backscattered ultrasound waveforms.

نویسندگان

  • Timothy A Bigelow
  • Michael L Oelze
  • William D O'Brien
چکیده

Quantitative ultrasound techniques using backscattered echoes have had limited success in vivo due to the frequency-dependent attenuation along the entire propagation path masking the frequency dependence of the backscatter. Herein, total attenuation and scatterer size are estimated simultaneously by an analysis of the in vivo backscattered power spectrum using two approaches. The simulations used to evaluate the two approaches used frequencies between 4 and 11 MHz with an effective scatterer radius of 25 microm. The first approach was based on approximations of the in vivo backscattered power spectrum (i.e., assumed Gaussian function), wherein attenuation and size were estimated by assuming each was a Gaussian transformation performed on Gaussian power spectra. The approach had poor accuracy due to the backscattered power spectra not being sufficiently modeled by a Gaussian function. The second approach estimated attenuation and size by fitting a modified reference spectrum to the in vivo backscattered power spectrum without any assumptions about the shape of the spectrum. The accuracy of the size estimate was better than 20% for signal-to-noise ratio >6 dB, window lengths greater than 4 mm, and attenuation between 0 and 1 dB/cm-MHz. However, the precision quickly degraded with increasing noise, increasing attenuation, and decreasing window length.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of local attenuation approximations when estimating correlation length from backscattered ultrasound echoes.

Estimating the characteristic correlation length of tissue microstructure from the backscattered power spectrum could improve the diagnostic capability of medical ultrasound. Previously, size estimates were obtained after compensating for source focusing, the frequency-dependent attenuation along the propagation path (total attenuation), and the frequency-dependent attenuation in the scattering...

متن کامل

Signal processing strategies that improve performance and understanding of the quantitative ultrasound SPECTRAL FIT algorithm.

Quantifying the size of the tissue microstructure using the backscattered power spectrum has had limited success due to frequency-dependent attenuation along the propagation path, thus masking the frequency dependence of the scatterer size. Previously, the SPECTRAL FIT algorithm was developed to solve for total attenuation and scatterer size simultaneously [Bigelow et al., J. Acoust. Soc. Am. 1...

متن کامل

Scatterer size estimation in pulse-echo ultrasound using focused sources: theoretical approximations and simulation analysis.

The speckle in ultrasound images has long been thought to contain information related to the tissue microstructure. Many different investigators have analyzed the frequency characteristics of the backscattered signals to estimate the scatterer acoustic concentration and size. Previous work has been mostly restricted to unfocused or weakly focused ultrasound sources, thus limiting its implementa...

متن کامل

Ultrasound attenuation estimation using backscattered echoes from multiple sources.

The objective of this study was to devise an algorithm that can accurately estimate the attenuation along the propagation path (i.e., the total attenuation) from backscattered echoes. It was shown that the downshift in the center frequency of the backscattered ultrasound echoes compared to echoes obtained in a water bath was calculated to have the form Deltaf=mf(o)+b after normalizing with resp...

متن کامل

Scatterer Size Estimation Using a Generalized Ultrasound Attenuation-compensation Function to Correct for Focusing

The frequency statistics of the backscattered waveform observed between tissue boundaries can be matched to a model to estimate the characteristic size of the scatterer in the tissue region of interest. In the past, the models have all assumed plane wave propagation requiring the use of unfocused or weakly focused sources in the experiment. In our work, we challenged this assumption by re-deriv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 117 3 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2005