Direct determination of diffusion coefficients of substrate and product by chronoamperometric techniques at microelectrodes for any level of ionic support.

نویسندگان

  • Wojciech Hyk
  • Anna Nowicka
  • Zbigniew Stojek
چکیده

A new method for the determination of the diffusion coefficients of both the substrate, DS, and the product, DP, of an electrode process has been developed. The method proposed is based on the analysis of the transient currents and can be applied to some reactions of the type SzS = PzP + ne and, in contrast to the concept based on the steady-state current, to any ratio of the concentrations of supporting electrolyte and substrate. The diffusion coefficients can be evaluated sequentially from the two parts of the double-potential step chronoamperogram, since the magnitude of the normalized chronoamperometric current of the first step depends on the DS value, while that of the second step is controlled by both DS and DP values. The corresponding, easy-to-use equations and procedures are given in the paper. The equations were derived on the basis of the numerical simulation data. The proposed methods of determination of diffusion coefficients for the substrates and products have been examined experimentally with the charged and uncharged ferrocene derivatives under diffusional and mixed diffusion-migration conditions. Only the chronoamperometric DS values obtained for the substrates could be compared to those determined from the steady-state diffusional current. It was found that for the systems investigated the agreement between these two methods was good. In this limited comparison, the standard deviations for the transient techniques were slightly larger than those obtained for the excess supporting electrolyte steady-state voltammetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surface Modification of Glassy Carbon Electrode by Ni-Cu Nanoparticles as a Competitive Electrode for Ethanol Electro-Oxidation

In the present study, Nickel-Copper nanoparticles were electrodeposited on glassy carbon electrode (GCE) by using electroplating deposition method. The prepared electrode was characterized by scanning electron microscopy (SEM) and elemental mapping analysis. Results showed that Ni-Cu nanoparticles with a high density are distributed at the surface of the glassy carbon electrode. Subsequentl...

متن کامل

Synergistic Signal Amplification Based on Ionic Liquid-BaTiO3 Nanoparticle Carbon Paste Electrode for Sensitive Voltammetric Determination of Acetaminophen

Monitoring the acetaminophen in biological samples and also in pharmaceutical formulations is important due to the concerns of public health care and drug safety. In this work a carbon paste electrode modified with BaTiO3 nanoparticle (BTO NPs) and room-temperature ionic liquid (IL) (n-hexyl-3-methylimidazolium hexafluoro phosphate) was fabricated. The direct electro-oxidation behavior of aceta...

متن کامل

Chronoamperometric Determination of Solid State Diffusion Coefficients in Copper-Gold Alloys Using a Molten Salt Electrolyte

für Naturforschung in cooperation with the Max Planck Society for the Advancement of Science under a Creative Commons Attribution 4.0 International License. Dieses Werk wurde im Jahr 2013 vom Verlag Zeitschrift für Naturforschung in Zusammenarbeit mit der Max-Planck-Gesellschaft zur Förderung der Wissenschaften e.V. digitalisiert und unter folgender Lizenz veröffentlicht: Creative Commons Namen...

متن کامل

Generalized theory of steady-state voltammetry without a supporting electrolyte. Effect of product and substrate diffusion coefficient diversity.

A generalized theory of the steady-state voltammetric response of a microelectrode in the absence of supporting electrolyte and for any values of diffusion coefficients of the substrate and the product of an electrode process is presented. The treatment applies to any reasonable combination of the charge numbers of the substrate, its counterion, and the product. A way to incorporate the activat...

متن کامل

Biokinetic coefficients determination of a MBR for styrene and ethylbenzene as substrate base on Andrews model

In this study, a lab-scale membrane bioreactor (MBR) was operated for a period of more than 10 months to determine the biokinetic coefficients of the system under the hydraulic retention times (HRT) of 20, 15 and 10 hrs and sludge retention times (SRT) of 5-20 days. The results revealed that the biological removal efficiency of styrene and ethylbenzene at a solid retention time of 20 day and a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 74 1  شماره 

صفحات  -

تاریخ انتشار 2002