Plethysmograph and interrupter resistance measurements in prematurely born young children.

نویسندگان

  • M R Thomas
  • G F Rafferty
  • R Blowes
  • J L Peacock
  • N Marlow
  • S Calvert
  • A Milner
  • A Greenough
چکیده

BACKGROUND Airways obstruction in premature infants is often assessed by plethysmography, which requires sedation. The interrupter (Rint) technique does not require sedation, but has rarely been examined in children under 2 years of age. OBJECTIVE To compare Rint results with plethysmographic measurements of airway resistance (Raw) in prematurely born, young children. DESIGN Prospective study. SETTING Infant and Paediatric Lung Function Laboratories. PATIENTS Thirty children with a median gestational age of 25-29 weeks and median postnatal age of 13 months. INTERVENTIONS AND MAIN OUTCOME MEASURES The infants were sedated, airway resistance was measured by total body plethysmography (Raw), and Rint measurements were made using a MicroRint device. Further Raw and Rint measurements were made after salbutamol administration if the children remained asleep. RESULTS Baseline measurements of Raw and Rint were obtained from 30 and 26 respectively of the children. Mean baseline Rint values were higher than mean baseline Raw results (3.45 v 2.84 kPa/l/s, p = 0.006). Limits of agreement for the mean difference between Rint and Raw were -1.52 to 2.74 kPa/l/s. Ten infants received salbutamol, after which the mean Rint result was 3.6 kPa/l/s and mean Raw was 3.1 kPa/l/s (limits of agreement -0.28 to 1.44 kPa/l/s). CONCLUSION The poor agreement between Rint and Raw results suggests that Rint measurements cannot substitute for plethysmographic measurements in sedated prematurely born infants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A flow interruption device for measurement of airway resistance.

Unlike conventional methods, the interrupter method for measuring airway resistance is non-invasive and requires minimal patient co-operation. It can therefore be applied in critically ill patients, acute asthmatics, neonates, pre-school children, geriatric patients and unconscious patients. The method is based on transient interruption of airflow at the mouth for a brief period during which al...

متن کامل

Lung function measurement in awake young children.

The aim of the study was to evaluate methods applicable in a clinical setting for monitoring of changes in lung function in awake young children. Impedance measurements by the impulse oscillation technique (ZIOS), respiratory resistance measurements by the interrupter technique (Rint) and transcutaneous measurements of oxygen tension (Ptc,O2) were compared with concomitant measurements of speci...

متن کامل

Observer variability of lung function measurements in 2-6-yr-old children.

The aim of this study was to assess the within-observer and between-observer variability of lung function measurements in children aged 2-6 yrs. Two observers examined 22 asthmatic children independently according to a predefined protocol. Each observer obtained duplicate measurements of respiratory resistance by the interrupter technique (Rint), respiratory resistance (Rrs,5) and reactance (Xr...

متن کامل

A portable device based on the interrupter technique for measuring airway resistance in preschool children.

The interrupter technique for measuring airway resistance is a noninvasive method reported to require minimal subject cooperation. Therefore it has a good potential for use in young children who are not able to cooperate with conventional lung function tests. The interrupter method is based on transient interruption of airflow at the mouth for a brief period during which alveolar pressure equil...

متن کامل

How should airways resistance be measured in young children: mask or mouthpiece?

The reproducibility and acceptability of airways resistance measurements using the interrupter technique (MicroRint) obtained using a mouthpiece were compared with those using a face mask. Fifty children aged 4-7 yrs performed four sets of six Rint measurements; two using a mouthpiece and two using a face mask with integral mouthpiece. Complete data were obtained from 45 (90%) children using th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of disease in childhood. Fetal and neonatal edition

دوره 91 3  شماره 

صفحات  -

تاریخ انتشار 2006