An improved method for the flow-injection determination of iodine using the luminol chemiluminescence reaction in a reversed micellar medium of cetyltrimethylammonium chloride in 1-hexanol-cyclohexane.

نویسندگان

  • Terufumi Fujiwara
  • Imdad U Mohammadzai
  • Mai Kojima
  • Takahiro Kumamaru
چکیده

To eliminate the use of chlorinated hydrocarbons, we have improved the method for the flow-injection (FI) determination of iodine based on the chemiluminescence reaction of iodine with luminol in a chloroform-free reversed micellar medium of the surfactant cetyltrimethylammonium chloride (CTAC) using a mixture of 1-hexanol-cyclohexane as a bulk solvent. The FI procedure used simply involves the mixing of an iodine solution in cyclohexane with the chemiluminescent reagent solution of luminol in the reversed micellar medium of CTAC in 0.38 M 1-hexanol in cyclohexane/water (buffered with sodium carbonate). The optimum conditions for the iodine determination were evaluated and a detection limit (DL) of 0.05 ng cm(-3) iodine was achieved. The calibration graph obtained was linear with a dynamic range from the DL to 10 ng cm(-3) iodine. The relative standard deviations (n=5) observed at all concentrations within the linear range were less than 2.5%. The improved FI method is rapid and equally sensitive like the original one and was found to be suitable for the determination of trace iodine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Catalytic behavior of tris(2,2'-bipyridine)iron(II) complex in chemiluminescence reaction of luminol in reversed micellar medium of cetyltrimethylammonium chloride.

Tris(2,2'-bipyridine) complex of iron(II) was found to cause an increase in the chemiluminescence (CL) emission of luminol dispersed in the reversed micellar medium of cetyltrimethylammonium chloride (CTAC) in 1:1 (v/v) dichloromethane-cyclohexane/water, when the iron(II) complex in dichloromethane was mixed directly with the reversed micellar solution containing luminol. Visible absorption mea...

متن کامل

Effect of Oxovanadium(IV) Acetylacetonate on the Chemiluminescence Reaction of Luminol in Reverse Micelles

Upon mixing of oxovanadium(IV) acetylacetonate, this complex caused an increase in the chemiluminescence (CL) of luminol in a reverse micellar medium of cetyltrimethylammonium chloride in chloroform-cyclohexane (6:5 vlv)-water (buffered with NaOH-Na2C03, pH 12.5) even in the absence of an oxidizing reagent such as hydrogen peroxide. In this CL process, the reaction of Luminol with the oxovanadi...

متن کامل

Chemiluminescence Determination of Atropine using Luminol-Hemin-H2O2 System

A sensitive and fast chemiluminescence (CL) method has been described for the direct determination of atropine. The method is based on the quenching effect of atropine on the CL signals of the luminol– H2O2 reaction catalyzed by hemin in an alkaline medium. Hemin could strongly enhance the chemiluminescence of the luminol–H2O2 system. The luminophor of the luminol–H2O2–hemin CL system was ident...

متن کامل

Acid-base behavior of rhodamine B in a reversed micellar medium of cetyltrimethylammonium chloride in 1-hexanol-cyclohexane/water.

The acid-base behavior of rhodamine B (RB) in reversed micellar solutions of cetyltrimethylammonium chloride (CTAC) in 1-hexanol-cyclohexane/water was investigated through absorption and fluorescence measurements under varying the hydrogen-ion concentration in a water pool, the mole fraction of 1-hexanol in a bulk solvent and the water to surfactant molar concentration ratio. RB exhibited equil...

متن کامل

Cetyltrimethylammonium bromide-enhanced chemiluminescence determination of uric acid using a luminol-hexacyanoferrate(III)-hexacyanoferrate(II) system.

A chemiluminescence (CL) method using flow injection (FI) was developed for the determination of uric acid based on the enhancement chemiluminescence intensity of luminol-hexacyanoferrate(III)-hexacyanoferrate(II) in the presence of cetyltrimethylammonium bromide and the uric acid species. The linear range was 7.0 x 10(-10) - 9.0 x 10(-7) M with a detection limit (3sigma) of 2.58 x 10(-10) M, w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 2006