Modelling of Device Driver Software by Reflection of the Device Hardware Structure
نویسنده
چکیده
Embedded systems are highly optimised to operate in the physical world they are embedded to. Hence, dedicated peripheral devices are designed which need support by a device driver to raise the level of abstraction for the application programmer. Even with methods of hardware/software co-design, devices and drivers are still designed by two designer groups. This paper depicts a systematic approach to design the coarse grained structure of the device driver by reflection and mapping of the internal structure of the device hardware. Even though common operating systems are programmed in a functional programming language, means of object-oriented programming languages and design pattern are applied.
منابع مشابه
Early Health Economic Modelling – Optimizing Development for Medical Device Developers?; Comment on “Problems and Promises of Health Technologies: The Role of Early Health Economic Modeling”
This commentary considers the positive and negative consequences of early economic modelling and explores potential future directions. Early economic modelling offers device manufacturers an opportunity to assess the potential value of an innovation at an early stage of development. Early modelling can direct resources into potentially viable technologies and reduce inv...
متن کاملDevelopment of A Head Docking Device for Linac-based Stereotactic Radiosurgery System to be Installed on Neptun 10 PC Linac
Introduction: Stereotactic radiosurgery is a technique for the treatment of intracranial lesions with highly collimated x-ray beam. Linac-based radiosurgery is currently performed by two techniques: couch or pedestal mounted. In the first technique, a device is required to affix patient's head to a couch and moreover to translate it accurately. Structure of suc...
متن کاملDESIGN AND STRUCTURE OF A NEW DEVICE FOR AUDITORY ELECTRICAL STIMULATION FOR SUPPRESSION OF TINNITUS
Auditory Electrical Stimulation for Tinnitus Suppression Tinnitus is the conscious experience of sound which arises in the head of its owner, but without a voluntary origin obvious to that person. About 10-15% of all adults report prolonged spontaneous tinnitus (PST). There are a lot of methods for suppressing this complaint. One of these methods is electrical stimulation. Electrical stimu...
متن کاملImproved drain current characteristics of tunnel field effect transistor with heterodielectric stacked structure
In this paper, we proposed a 2-D analytical model for electrical characteristics such as surface potential, electric field and drain current of Silicon-on-Insulator Tunnel Field Effect Transistor (SOI TFETs) with a SiO2/High-k stacked gate-oxide structure. By using superposition principle with suitable boundary conditions, the Poisson’s equation has been solved to model the channel r...
متن کاملImplant Removal Matrix for the Upper Extremity Orthopedic Surgeon
Orthopedic implant removal is a commonly performed procedure. While implant removal can be associated withimproved symptoms, risks of the surgery are notable. Stripped screws, broken and retained hardware, and morbidityassociated with soft tissue compromise during difficult removal are all common. Familiarity with the instruments iscritical to procedure success. The purpose of...
متن کامل