Enhanced coagulation using a magnetic ion exchange resin.
نویسندگان
چکیده
The objective of this investigation was to examine the effectiveness of a magnetic ion exchange resin (MIEX) to enhance the coagulation of disinfection by-product precursors in nine surface waters, each representing a different element of the USEPA's 3 x 3 enhanced coagulation matrix. The effect of MIEX-pretreatment on the requisite alum dose needed for subsequent coagulation of turbidity was also evaluated. Enhanced coagulation with MIEX was found to be very effective for removing trihalomethane (THM) and haloacetic acid (HAA) precursors from the nine waters examined. THM and HAA formation potential was reduced by more than 60% in all of the waters studied; reductions approaching 90% were seen in the waters with the highest specific ultraviolet absorbance values. The residual total organic carbon concentration, ultraviolet absorbance, and THM and HAA formation potential were all substantially lower as a result of MIEX and alum treatment compared to alum coagulation alone. MIEX pre-treatment also lowered the coagulant demand of each of the waters substantially.
منابع مشابه
Biocompatibility research of a novel pH sensitive ion exchange resin microsphere
The main objective of this study was to investigate biocompatibility and provide in vivo pharmacological and toxicological evidence for further investigation of the possibility of pH sensitive ion exchange resin microsphere for clinical utilizations. Acute toxicity study and general pharmacological studies were conducted on the pH sensitive ion exchange resin microsphere we prepared. The genera...
متن کاملIon-exchange, an Approach to Prepare an Oral Floating Drug Delivery System for Diclofenac
Using ion-exchange resins, a multiple-unit type of oral floating dosage system has been prepared to prolong gastric emptying time of dosage form. The system is composed of beads of drug-resin complex, which are loaded with bicarbonate ions and coated with a hydrophobic polymer. The system is so designed that when the beads reach the stomach, chloride ions are exchanged with bicarbonate and drug...
متن کاملBiocompatibility research of a novel pH sensitive ion exchange resin microsphere
The main objective of this study was to investigate biocompatibility and provide in vivo pharmacological and toxicological evidence for further investigation of the possibility of pH sensitive ion exchange resin microsphere for clinical utilizations. Acute toxicity study and general pharmacological studies were conducted on the pH sensitive ion exchange resin microsphere we prepared. The genera...
متن کاملHigh Performance Nanocomposite Cation Exchange Membrane: Effects of Functionalized Silica-Coated Magnetic Nanoparticles
Nanocomposite cation exchange membranes (CEMs) were prepared by adding various amounts of functionalized silica-coated magnetite nanoparticles to the sulfonated polyethersulfone (sPES) polymeric matrix. The particles were synthesized first by the co-precipitation method (M0). Different surface modifications were then carried out on them by grafting three functional groups of mercaptopropyl, pro...
متن کاملIon-exchange, an Approach to Prepare an Oral Floating Drug Delivery System for Diclofenac
Using ion-exchange resins, a multiple-unit type of oral floating dosage system has been prepared to prolong gastric emptying time of dosage form. The system is composed of beads of drug-resin complex, which are loaded with bicarbonate ions and coated with a hydrophobic polymer. The system is so designed that when the beads reach the stomach, chloride ions are exchanged with bicarbonate and drug...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Water research
دوره 36 16 شماره
صفحات -
تاریخ انتشار 2002