Corrosion at the Head-Neck Junction: Why Is This Happening Now?
نویسنده
چکیده
While mechanically-assisted crevice corrosion (MACC) at the head/neck junction of modular total hip arthroplasty (THA) femoral components was first described over two decades ago, it is only within the last few years that investigators have observed that adverse local tissue reactions (ALTRs) associated with MACC are an increasingly prevalent mode of failure of contemporary THAs. As yet, the incidence, etiology and pathogenesis of MACC-associated ALTR are not well understood. In this review, possible implant-, patient-, and surgeon-related factors are considered in the context of a small but growing body of evidence from laboratory simulations, implant and tissue retrieval studies and clinical case series. It is likely that MACC-associated ALTR is a multifactorial process and that ongoing research will lead to multiple strategies that will facilitate early diagnosis and ultimately prevention of the adverse clinical sequelae of this phenomenon.
منابع مشابه
Head-Neck Taper Corrosion in Hip Arthroplasty
Modularity at the head-neck junction of the femoral component in THA became popular as a design feature with advantages of decreasing implant inventory and allowing adjustment of leg length, offset, and soft tissue balancing through different head options. The introduction of a new modular interface to femoral stems that were previously monoblock, or nonmodular, comes with the potential for cor...
متن کاملCorrosion and adverse local tissue reaction after total hip arthroplasty with a modular titanium alloy femoral neck
This report describes a case of mechanically assisted crevice corrosion and secondary adverse local tissue reaction in a patient following a total hip arthroplasty, utilizing a modular neck (bi-modular) femoral component. Radiographic evaluation demonstrated a well-positioned, stable, cementless arthroplasty. Upon further evaluation, the patient had elevated serum cobalt and chromium levels, an...
متن کاملFretting and Corrosion Damage at the Head-Neck Taper is Reduced with Ceramic Femoral Heads: A Retrieval Study
Introduction: Modular head-neck total hip arthroplasty (THA) offers several benefits for orthopaedic surgeons, including intraoperative flexibility and the ability to change the head at revision surgery [1]. However, modularity at the head-neck taper, especially the use of metallic heads and stems, can lead to fretting and corrosion at the taper junction, leading to metal ions and debris releas...
متن کاملMechanically assisted crevice corrosion of the head-neck taper in a large head metal-on-metal total hip arthroplasty
Taper corrosion of the head-neck junction is a potentially significant and devastating problem facing orthopedic surgeons. We present a case of a 53 year old male who presented for routine follow up for a left, large head, metal on metal total hip arthroplasty five years out. The patient was asymptomatic at the visit. X-rays at the time demonstrated a large amount of medial calcar osteolysis. S...
متن کاملA Case of a C-Stem Fracture at the Head-Neck Junction and a Review of the Literature
We report the first case of a fracture of the standard C-stem in combination with a large metal-on-metal articulation. This occurred at the head-neck junction. Analysis of the fractured stem showed evidence of fatigue failure with possible corrosion. The use of large femoral heads with neck adaptors and narrow tapers should be used with caution, especially in heavy, active patients.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 31 7 شماره
صفحات -
تاریخ انتشار 2016