Comparative aqueous outflow facility measurements by pneumatonography and Schiotz tonography.
نویسندگان
چکیده
Tonography was performed on 36 eyes of 15 normal and 3 primary open angle glaucoma patients using pneumatonography and classical Schiotz tonography. The average values of the coefficient of outflow facility (C) for the whole sample were virtually identical with both methods. However, both intersubject and interobserver variability were significantly higher with penumatonography. Although both methods provide comparable aggregate estimates of aqueous outflow facility, we think that Schiotz tonography is more reliable than pneumatonography because of the greater mechanical stability of the Schiotz instrument on the eye. On the other hand, pneumatonography offers the advantage of a shorter test period (2 min instead of 4).
منابع مشابه
Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography
Purpose It is not known if outflow facilities measured by pneumatonography and Schiøtz tonography are interchangeable. In this study we compared outflow facility measured by pneumatonography to outflow facility measured by digital Schiøtz tonography. Methods Fifty-six eyes from 28 healthy participants, ages 41 to 68 years, were included. Intraocular pressure (IOP) was measured in the sitting ...
متن کاملAqueous humor outflow facility by tonography does not change with body position.
PURPOSE Intraocular pressure (IOP) varies with body position and previous research has indicated that most, but not all, of the variation in IOP is due to changes in episcleral venous pressure (EVP). Positional changes in other aqueous humor dynamic parameters may contribute to the change in IOP. The purpose of this study was to investigate the variation of aqueous humor outflow facility with b...
متن کاملEffect of Tonography on Facility of Outflow.
In enucleated stored eyes facility of outflow is diminished by large corneal distortions. The radius of distortion at which decrease in facility is noted is related to the shape of the distortion. Of the three distorting devices tested, a plane surface decreased the facility at the smallest radius of distortion, a convex surface was intermediate in effect, while the Schiotz tonometer allowed th...
متن کاملMechanism of Action of Selective Laser Trabeculoplasty and Predictors of Response
Purpose This study was designed to evaluate the changes in aqueous humor dynamics (AHD) produced by selective laser trabeculoplasty (SLT) and to explore if baseline AHD parameters are predictive of IOP response to SLT. Methods Thirty-one consecutive subjects diagnosed with ocular hypertension or primary open-angle glaucoma scheduled to undergo SLT as their primary IOP-lowering therapy were en...
متن کاملEicosanoids as a new class of ocular hypotensive agents. 2. Comparison of the apparent mechanism of the ocular hypotensive effects of A and F type prostaglandins.
It has recently been shown that derived prostaglandins (PGs) of the A and B types are much more potent ocular hypotensive agents than primary PGs of the E, F, or D type. The purpose of this study was to determine whether two representatives of these structurally different PGs, namely PGA2 and PGF2 alpha-1-isopropyl ester (PGF2 alpha IE), reduce intraocular pressure (IOP) of the feline eye by si...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 27 12 شماره
صفحات -
تاریخ انتشار 1986