Recently, power quality (PQ) has because a significant issue for both power supplies and customers. Researchers in all developed countries know that power quality is one of the factors of losses in the network. Increasing power electronic equipment changes current waveform in distribution networks and this can cause many problems in networks. Distortion of voltage waveforms results in the appearance of harmonic and sometimes non-harmonic frequencies in the network voltage. Harmonic distortions on the network voltage can cause additional losses and heating of certain network equipment, faulty operation of control equipment, an increase in peak voltage and disturbance and interference in neighbouring telecommunication systems. This paper will investigate the effect of harmonic on the sample distribution network losses and then the capacity of transmission lines. The harmonic studies consist of site background harmonic measurements at the existing local distribution substations, and computer-based system modelling based on site measured results. For modeling of system in computer we used ETAP power station software.
منابع مشابه
Simultaneous Placement of Capacitor and DG in Distribution Networks Using Particle Swarm Optimization Algorithm
Nowadays, using distributed generation (DG) resources, such as wind and solar, also improving the voltage profile in distribution companies has been considered. As optimal placement and sizing of shunt capacitors become more prevalent, utilities want to determine the impact of the various capacitors placement in distribution systems. Locating and determining the optimal capacity of shunt capaci...
متن کاملFault Locating in High Voltage Transmission Lines Based on Harmonic Components of One-end Voltage Using Random Forests
In this paper, an approach is proposed for accurate locating of single phase faults in transmission lines using voltage signals measured at one-end. In this method, harmonic components of the voltage signals are extracted through Discrete Fourier Transform (DFT) and are normalized by a transformation. The proposed fault locator, which is designed based on Random Forests (RF) algorithm, is train...
متن کاملDesign and Control of a Novel hybrid Active Power Filter based on Load Harmonic Currents Separation with the aim of DC-link voltage minimization in voltage source converter
This paper proposes a new hybrid active power filter, including voltage source converter (VSC) based active power filter and Thyristor Controllable LC Passive Filter (TCLC-HAPF) for eliminating harmonic load current components and compensating reactive power. This new structure which is based on the separation of high and low-frequency components of load current idea can reduce the drawbacks of...
متن کاملHarmonic Reduction Technique Using Flying Capacitor Based Z Source Inverter for a DVR
The Dynamic Voltage Restorer (DVR) is a commercially available, popular device to eliminate voltage sags and swells in the distribution lines. Its basic function is to inject the voltage difference (difference between the pre-sag and sag voltage) to the power line and maintains the pre-sag voltage condition in the load side. The efficiency of the DVR depends on the performance of the efficiency...
متن کاملDistributed Generation Effects on Unbalanced Distribution Network Losses Considering Cost and Security Indices
Due to the increasing interest on renewable sources in recent years, the studies on integration of distributed generation to the power grid have rapidly increased. In order to minimize line losses of power systems, it is crucially important to define the size and location of local generation to be placed. Minimizing the losses in the system would bring two types of saving, in real life, one is ...
متن کامل