Cerebral protection devices for use during carotid artery angioplasty with stenting: a health technology assessment.

نویسندگان

  • Devidas Menon
  • Tania Stafinski
چکیده

OBJECTIVES This study sought to examine the safety, efficacy, and economic implications of the use of cerebral protection devices during carotid artery angioplasty and stenting (CAS) in high-risk patients with severe carotid artery disease (CAD). METHODS A comprehensive search for peer- and non-peer-reviewed studies that compared carotid endarterectomy (CEA) or CAS without cerebral protection to CAS with cerebral protection and appeared in the English language literature between January 1990 and January 2005 was completed. Information from studies identified was extracted using a common data abstraction form and then critically appraised against published quality assessment criteria. RESULTS Of the eight studies found, six provided information on technical or procedural success rates, with values ranging from 95.6 percent to 100 percent. Three of the four studies comparing groups of patients who received CAS with cerebral protection with those who received only CAS reported a non-statistically significantly higher 30-day incidence of death and stroke (major or minor) in the latter group. None of the three studies comparing CAS with cerebral protection to CEA demonstrated a statistically significant difference in the 30-day incidence of death, major stroke, or myocardial infarction between treatment groups. No economic analyses were found. CONCLUSIONS In high-risk patients with severe CAD, the evidence suggests that CAS with cerebral protection may offer a safe and efficacious alternative to CEA, reducing the risk of embolic peri-procedural complications associated with CAS to acceptable levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES

Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...

متن کامل

Cerebral protection devices for use during carotid artery stenting.

(1) Cerebral protection devices offer a new approach to reducing the risk of stroke and death in patients undergoing carotid angioplasty with stenting (CAS). (2) Nine studies have examined the efficacy of cerebral protection devices, by comparing the incidence of procedure related stroke and death to that of CAS without protection, and to surgical endarterectomy. Few of the studies were of high...

متن کامل

Carotid angioplasty and stenting in a patient with high grade stenosis of Internal Carotid Artery associated with both vertebral arteries and contralateral carotid occlusion

Severe internal carotid artery (ICA) stenosis is a common cause of cerebrovascular accident (CVA) in middle-aged patients. Contralateral carotid occlusion (CCO) in patients with severe ICA stenosis is associated with high risk of CVA. Carotid endarterectomy (CEA) is associated with more complications in patients with CCO than those without CCO. In this study, we present the case of a 61-year-ol...

متن کامل

An experience with angioplasty and stenting of carotid artery stenosis with embolic protection devices.

BACKGROUND Carotid artery stenting has recently been recommended as an alternative to carotid endarterectomy by some clinicians. OBJECTIVE To evaluate success rate, as well as in-hospital and 30-day adverse events in our first experience in Iran for carotid artery stenting with protection devices. METHODS From December 2003 through July 2004, we performed 12 consecutive (9 males and 3 femal...

متن کامل

Protected carotid stenting: clinical advantages and complications of embolic protection devices in 442 consecutive patients.

BACKGROUND AND PURPOSE Periprocedural embolization of debris during carotid stenting interventions may result in neurological deficit. This study was designed to evaluate in-hospital and 30-day adverse events in patients percutaneously treated for carotid artery disease with embolic protection devices. METHODS From 1999 to June 2002, a total of 442 consecutive patients underwent percutaneous ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of technology assessment in health care

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 2006