Ball Beating Lubrication in Refrigetation Compressors

نویسنده

  • B. Jacobson
چکیده

When the re:fiigerant R l34a is mixed with an ester oil and usea m compressor bearing lubrication, no EP action is experienced. The refrigerant contains no chlorine and the lubricant additives can not be chemically active like normal EP additives, not to deposit in and destroy the heat excha..>Jgers. The iubricant film thickness thus needs to be considerably larger for an Rl34a compressor bearing than for e.g. an R22 compressor bearing if the same service life should be expected for the two bearings. Typically 50% higher viscosity was needed for the R134a mixture to get a certain wear rate compared to ail R22 mixture giving the same wear rate. To avoid the problem with high wear rate at high re:fiigerant concentrations and to make it possible to run the compressor bearings with less oil an experimental investigation was performed. The experiments investigated the possibility to locally increase the oil concentration at the elastohydrodynamic contacts in the bearings to get better lubrication.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lubrication Analysis of Rotary Compressors for HFC Refrigerants

In this study, a practical numerical analysis has been developed in order to investigate the lubrication characteristics between a rolling piston and a crank of rotary compressors. This analysis is treated as a coupled problem of the momentum equations and the Reynolds equation of oil film. Using this analysis, the lubrication characteristics between the rolling piston and the crank for 2-cylin...

متن کامل

Water Lubrication of Stainless Steel using Reduced Graphene Oxide Coating

Lubrication of mechanical systems using water instead of conventional oil lubricants is extremely attractive from the view of resource conservation and environmental protection. However, insufficient film thickness of water due to low viscosity and chemical reaction of water with metallic materials have been a great obstacle in utilization of water as an effective lubricant. Herein, the frictio...

متن کامل

Important Parameters for Small, Twin-Screw Refrigeration Compressors

This paper deals with open-shaft twin-screw refrigeration compressors in the 10 175 m3/h (10 100 CFM) range. Applications for such compressors are, for example,external combustion engine heat-pumps and transport refrigeration. The twin-screw compressor concept is discussed from following view-points; operational mode and rotor housing design drive arrangement bearings lubricants cooling volume ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014