Comparison of the FiO2 delivered by seven models of the self-inflating bag-mask system.

نویسندگان

  • Armando Carlos Franco de Godoy
  • Ronan Josê Vieira
چکیده

BACKGROUND AND OBJECTIVES Since resuscitators with self-inflating bag-mask systems manufactured and/or commercialized in Brazil are widely available and used in health services, both out- and intra-hospitals, the objective of this study was to determine the O2 fractions delivered by seven resuscitators receiving different O2 flows. METHODS Seven resuscitators with self-inflating bag-mask systems were tested at the Respiratory Unit of the HC/UNICAMP. A wall O2 flowmeter was connected to the resuscitator that received an O2 flow of 1, 5, 10, and 15 L min(-1) and those were connected to a test lung. Resuscitators capable of being connected to an O2 reservoir were tested with and without this accessory Twenty consecutive measurements were performed and the mean determined. RESULTS Only one resuscitator delivered an O2 fraction slightly below the accepted limit (0.80) when used with the O2 reservoir. Without this device, all resuscitators achieved the minimal limit of O2 fraction (0.40). Resuscitators not capable of being connected to an O2 reservoir delivered a higher O2. CONCLUSIONS All resuscitators capable of being connected to an O2 reservoir delivered a higher O2 concentration when connected to this device. Resuscitators that do not have this capability delivered a higher O2 concentration than the ones that could be connected to this device but are used without it.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Emergency airway management by non-anaesthesia house officers--a comparison of three strategies.

OBJECTIVES The purpose of this study was to determine effects of different airway devices and tidal volumes on lung ventilation and gastric inflation in an unprotected airway. METHODS Thirty one non-anaesthesia house officers volunteered for the study, and ventilated a bench model simulating an unintubated respiratory arrest patient with bag-valve-facemask, laryngeal mask airway, and combitub...

متن کامل

Oxygen outflow delivered by manually operated self-inflating resuscitation bags in patients breathing spontaneously.

OBJECTIVE To determine the oxygen outflow delivered by seven different models of manually operated self-inflating resuscitation bags (with and without an oxygen reservoir connected), which were tested using different oxygen supply rates without manipulating the bag, by simulating their use in patients breathing spontaneously. METHODS The oxygen outflow was measured using a wall oxygen flow me...

متن کامل

An audible indication of exhalation increases delivered tidal volume during bag valve mask ventilation of a patient simulator.

Self-inflating manual resuscitators (SIMRs) can mislead caregivers because the bag, unlike a Mapleson-type device, reinflates even without patient exhalation. We added a whistle as an audible indicator to the exhalation port of a SIMR. In randomized order, each participant provided two sets of breaths via mask ventilation with a SIMR, one with and one without audible feedback, to a Human Patien...

متن کامل

Comparison of efficacy of three devices of manual positive pressure ventilation: a mannequin-based study

BACKGROUND We compared the efficacy of and consistency in manual ventilation by trained healthcare professionals using three devices: self-inflating bag, flow-inflating bag, and T-piece resuscitator. METHODS Prospective analytical study at a level III Neonatal unit of a tertiary care hospital. Forty participants (consultants, postgraduates, interns, and neonatal nurses - 10 each) manually ven...

متن کامل

Emergency airway management by intensive care unit nurses with the intubating laryngeal mask airway and the laryngeal tube

When using the laryngeal tube and the intubating laryngeal mask airway (ILMA), the medium-size (maximum volume 1100 ml) versus adult (maximum volume 1500 ml) self-inflating bags resulted in significantly lower lung tidal volumes. No gastric inflation occurred when using both devices with either ventilation bag. The newly developed medium-size self-inflating bag may be an option to further reduc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de anestesiologia

دوره 59 1  شماره 

صفحات  -

تاریخ انتشار 2009