Effects of variation of MRI parameters on signal homogeneity: a qualitative analysis for ferrous benzoic xylenon orange gel.

نویسندگان

  • Aalia Nazir
  • Muhammad Afzal
  • Saeed Ahmad Buzdar
چکیده

OBJECTIVE This study focuses on the diverse effects of MRI parameters on image quality using widely available imaging pulse sequences. METHODS A tissue equivalent gel system has been used for Magnetic Resonance Imaging by using Xylenol orange dye with Fricke-Benzoic solution which was formulated by Kelly R.G (1998). The gel system was radiated while using 6MV photons from Varian Clinic Linear Accelerator. RESULTS The qualitative analysis include the effect of TR and TE on signal nonuniformity according to which the escalating repetition time gives a uniform signal having the average values calculated are 0.76%, 0.83%, 1.43% and 1.89% for the conventional spin echo (CSE), fast spin echo (FSE), gradient recalled echo (GRE) and fluid attenuated inversion recovery (FLAIR) respectively. FLAIR showed contradictory results due to longitudinal relaxation of the signal. This is because, at the longer value of inversion time (TI), the signal from simple fluids is nulled, thus reducing signal intensity. CONCLUSION The evaluation of signal uniformity for different pulse sequences demonstrates that the repetition time (TR) affects the signal homogeneity as it maintains image quality for CSE and FSE. However, a careful selection is required for FLAIR due to its sensitive behaviour for image uniformity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Uncertainty Analysis in MRI-based Polymer Gel Dosimetry

Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...

متن کامل

Diffusion measurement in ferrous infused gel dosimeters

Background: The compositions of Ferrous sulphate, Agarose and Xylenol orange dye (FAX) and Ferrous sulphate, Gelatin and Xylenol orange dye (FGX) in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. Ionizing radiation causes oxidation of Fe2+ ion to Fe3+ ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours af...

متن کامل

An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter

Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...

متن کامل

اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی

Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JPMA. The Journal of the Pakistan Medical Association

دوره 60 6  شماره 

صفحات  -

تاریخ انتشار 2010