Multicenter evaluation of the fully automated COBAS AMPLICOR PCR test for detection of Chlamydia trachomatis in urogenital specimens.
نویسندگان
چکیده
The fully automated COBAS AMPLICOR CT/NG test for the detection of Chlamydia trachomatis was evaluated in a multicenter trial. Test performance was evaluated for 2,014 endocervical swab and 1,278 urine specimens obtained from women and for 373 urethral swab and 254 urine specimens obtained from men. Culture served as the reference test. Culture-negative, COBAS AMPLICOR-positive specimens that tested positive in a confirmatory PCR test for an alternative target sequence within the C. trachomatis major outer membrane protein gene were resolved as true positives. The overall prevalence of chlamydia was 4.3% in cervical swabs and 11.0% in urethral swabs from men. When the results for each specimen type were considered separately, the resolved sensitivities were 96.5% (83 of 86) for endocervical swab specimens, 95.1% (39 of 41) for urine specimens from women, 100.0% (41 of 41) for urethral swab specimens from men, and 94.4% (17 of 18) for urine specimens from men; the resolved specificities were 99.4% (1,912 of 1,924) for endocervical swab specimens, 99.8% (1,204 of 1,207) for urine specimens from women, 98. 5% (325 of 330) for urethral swab specimens from men, and 100.0% (236 of 236) for urine specimens from men. For the subset of patients from whom both swab and urine specimens were collected, the combined results for both specimen types were used to identify all infected patients. Using these combined reslts as criteria, the resolved sensitivities for the COBAS AMPLICOR test were 82.6% (38 of 46) for endocervical swab specimens, 84.4% (38 of 45) for urine specimens from women, 84.2% (16 of 19) for urethral swab specimens from men, and 89.5% (17 of 19) for urine specimens from men. In comparison, the sensitivity of culture was only 56.5% (26 of 46) for endocervical specimens and 63.2% (12 of 19) for urethral specimens from men. The internal control provided in the COBAS AMPLICOR test revealed that 2.9% of specimens were inhibitory when they were initially tested. Nevertheless, valid results were obtained for 99. 1% of specimens because 68.7% of the inhibitory specimens were not inhibitory when a second aliquot of the original sample was tested. Two additional COBAS AMPLICOR-positive specimens were detected by retesting inhibitory specimens. The COBAS AMPLICOR CT/NG test for the detection of C. trachomatis exhibited equally high sensitivities and specificities with both urogenital swab and urine specimens and, thus, is well-suited for use in screening.
منابع مشابه
Multicenter evaluation of the AMPLICOR and automated COBAS AMPLICOR CT/NG tests for detection of Chlamydia trachomatis.
The fully automated COBAS AMPLICOR CT/NG and semiautomated AMPLICOR CT/NG tests were evaluated in a multicenter trial for the ability to detect Chlamydia trachomatis infections. Test performance compared to that of culture was evaluated for 2,236 matched endocervical swab and urine specimens obtained from women and for 1,940 matched urethral swab and urine specimens obtained from men. Culture-n...
متن کاملPreparation and validation of PCR-generated positive controls for diagnostic dot blotting.
References 1. Loeffelholz MJ, Lewinski CA, Silver SR, Purohit AP, Herman SA, Buonagurio DA, Dragon EA. Detection of Chlamydia trachomatis in endocervical specimens by polymerase chain reaction. J Clin Microbiol 1992;30:2847–51. 2. Bass CA, Jungkind DL, Silverman NS, Bondi JM. Clinical evaluation of a new polymerase chain reaction assay for detection of Chlamydia trachomatis in endocervical spec...
متن کاملPreservCyt transport medium used for the ThinPrep Pap test is a suitable medium for detection of Chlamydia trachomatis by the COBAS Amplicor CT/NG test: results of a preliminary study and future implications.
The commercial COBAS Amplicor CT/NG test (Roche Diagnostic Systems, Meylan, France) is a sensitive and specific method for detection of Chlamydia trachomatis infections. This test currently consists of using a nucleic acid amplification method to detect C. trachomatis in first-void urine specimens and in endocervical swabs collected in 2-sucrose-phosphate (2SP) transport medium. We conducted a ...
متن کاملValidation of roche COBAS Amplicor assay for detection of Chlamydia trachomatis in rectal and pharyngeal specimens by an omp1 PCR assay.
Screening guidelines for men who have sex with men (MSM) recommend testing of extragenital sites (pharyngeal and rectal) for gonorrhoea and chlamydia. Testing of specimens from these sites is not validated by most commercial nucleic amplification tests, such as the COBAS Amplicor assay. To investigate the utility of the COBAS Amplicor assay for detection of Chlamydia trachomatis in extragenital...
متن کاملComparison between the LCx Probe system and the COBAS AMPLICOR system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae infections in patients attending a clinic for treatment of sexually transmitted diseases in Amsterdam, The Netherlands.
Two assays for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae were compared: the LCx Probe system (the LCx system; Abbott Diagnostic Laboratories, North Chicago, Ill.) and the COBAS AMPLICOR C. trachomatis/N. gonorrhoeae system (the COBAS AMPLICOR system; Roche Diagnostic Systems, Branchburg, N.J.). Endocervical swab specimens, male urethral swab specimens, and female and male...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 37 1 شماره
صفحات -
تاریخ انتشار 1999