Dual-energy computed tomography has limited sensitivity for non-tophaceous gout: a comparison study with tophaceous gout

نویسندگان

  • Alan N. Baer
  • Tracie Kurano
  • Uma J. Thakur
  • Gaurav K. Thawait
  • Matthew K. Fuld
  • Janet W. Maynard
  • Mara McAdams-DeMarco
  • Elliot K. Fishman
  • John A. Carrino
چکیده

BACKGROUND Dual-energy computed tomography (DECT) is a new diagnostic tool for gout, but its sensitivity has not been established. Our goal was to assess the sensitivity of DECT for the detection of monosodium urate (MSU) deposits in non-tophaceous and tophaceous gout, both at the level of the patient and that of the individual joint or lesion. METHODS DECT was performed on 11 patients with crystal-proven non-tophaceous gout and 10 with tophaceous gout and included both the upper and lower extremities in 20/21 patients. DECT images were simultaneously acquired at 80 and 140 kV and then processed on a workstation with proprietary software using a two-material decomposition algorithm. MSU deposits were color coded as green by the software and fused onto grey-scale CT images. The number and location of these deposits was tallied independently by two DECT-trained radiologists blinded to the clinical characteristics of the patient. Sensitivity of DECT was defined as the proportion of patients with a confirmed diagnosis of gout which was correctly identified as such by the imaging technique. All patients provided informed consent to participate in this IRB-approved study. RESULTS MSU deposits were detected by DECT in ≥1 joint area in 7/11 (64 %) patients with non-tophaceous gout, but were only detected in 3/12 (25 %) joints proven by aspiration to be affected with gout. Inclusion of the upper extremity joints in the scanning protocol did not improve sensitivity. All 10 patients with tophaceous gout had MSU deposits evident by DECT. The sensitivity of DECT for individual gouty erosions was assessed in 3 patients with extensive foot involvement. MSU deposits were detected by DECT within or immediately adjacent to 13/26 (50 %) erosions. CONCLUSIONS A DECT protocol that includes all lower extremity joints has moderate sensitivity in non-tophaceous and high sensitivity in tophaceous gout. However, DECT has lower sensitivity when restricted to individual crystal-proven gouty joints in non-tophaceous disease or individual erosive lesions in tophaceous gout. The detection of MSU deposits by DECT relates to their size and density and the detection parameters of the DECT scanner and adjustment of the latter might improve sensitivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lack of change in urate deposition by dual-energy computed tomography among clinically stable patients with long-standing tophaceous gout: a prospective longitudinal study

INTRODUCTION Dual-energy computed tomography (DECT) has potential for monitoring urate deposition in patients with gout. The aim of this prospective longitudinal study was to analyse measurement error of DECT urate volume measurement in clinically stable patients with tophaceous gout. METHODS Seventy-three patients with tophaceous gout on stable therapy attended study visits at baseline and t...

متن کامل

Tophaceous gout causing lumbar stenosis

RATIONALE Gout in the spine is very rare. The clinical symptoms of the spinal gout are various and lack of specificity. The authors report a case of spinal gout causing lumbar stenosis. We never find such wide-invasive spinal gouty lesion in the published studies. PATIENT CONCERNS A 68-year-old male had low back pain radiating to bilateral lower limbs, accompanying with intermittent claudicat...

متن کامل

Urate crystal deposition and bone erosion in gout: ‘inside-out’ or ‘outside-in’? A dual-energy computed tomography study

BACKGROUND It is currently unknown whether bone erosion in gout occurs through an 'inside-out' mechanism due to direct intra-osseous crystal deposition or through an 'outside-in' mechanism from the surface of bone. The aim of this study was to examine the mechanism ('outside-in' vs. 'inside-out') of monosodium urate (MSU) crystal deposition in bone erosion in gout. Specifically, we used three-d...

متن کامل

Severe tophaceous gout. Characterization of low socioeconomic level patients from México.

OBJECTIVE To describe a group of patients with frequent tophaceous gout, the variables associated with severe tophaceous gout and to compare them with other patients with gout described elsewhere. METHODS We looked for 65 demographic clinical and paraclinical variables from patients with gout who attended our gout clinic from 1995-2000 and were evaluated by the same group of physicians. RES...

متن کامل

Imaging in gout - What can we learn from MRI, CT, DECT and US?

There are many exciting new applications for advanced imaging in gout. These modalities employ multiplanar imaging and allow computerized three-dimensional rendering of bone and joints (including tophi) and have the advantage of electronic data storage for later retrieval. High-resolution computed tomography has been particularly helpful in exploring the pathology of gout by investigating the r...