Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement.
نویسندگان
چکیده
BACKGROUND Arterial pressure (AP) monitoring should be accurate, easy to use, free of risks, and ideally continuous. The continuous non-invasive arterial pressure (CNAP) device is non-invasive and provides continuous pressure readings. This study was performed to compare the agreement of CNAP and invasive AP monitoring. METHODS Ninety patients undergoing surgery under general anaesthesia were enrolled. Invasive pressure monitoring was established at the radial artery. CNAP monitoring using a finger sensor recording was begun before induction of anaesthesia. Statistical analysis was conducted with the Bland-Altman method for comparisons of repeated measures. RESULTS We obtained 16 843 valid pressure readings from 85 patients. Mean (sd) bias during maintenance of anaesthesia was: systolic AP: 4.2 (16.5) mm Hg; mean AP (MAP): -4.3 (10.4) mm Hg; and diastolic AP: -5.8 (6) mm Hg. The results of a subgroup analysis of patients who had a mean intra-arterial pressure of <70 mm Hg were as follows: systolic pressure: -0.3 (9.7) mm Hg; mean pressure: -6.8 (7.6) mm Hg; and diastolic pressure: -7.9 (7.2) mm Hg. Bias and percentage error during the induction period were greater in both the main and subgroup analyses, probably due to recalibration being omitted after induction. CONCLUSIONS The CNAP monitor showed an acceptable agreement and was interchangeable with invasive pressure monitoring for MAP during normotensive conditions. During induction of anaesthesia and when the AP was low, the agreement was less good and interchangeability was not achieved. These results suggest that CNAP is not statistically equivalent to invasive monitoring during all periods of anaesthesia but may be a useful additional AP monitor.
منابع مشابه
Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کاملPresentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملMeasurement of mean arterial pressure: comparison of the Vasotrac monitor with the finger differential oscillometric device.
The Vasotrac monitor provides non-invasive near-continuous blood pressure monitoring and is designed to be an alternative to direct intra-arterial blood pressure (BP) measurement. As compared to radial artery invasive BP and upper arm non-invasive BP, Vasotrac readings have been found to have a good agreement with them. However, discrepancies have been reported when rapid changes in BP exist. I...
متن کاملComparison of continuous non-invasive finger arterial pressure monitoring with conventional intermittent automated arm arterial pressure measurement in patients under general anaesthesia.
BACKGROUND For a majority of patients undergoing anaesthesia for general surgery, mean arterial pressure (MAP) is only measured intermittently by arm cuff oscillometry (MAPiNIAP). In contrast, the Nexfin(®) device provides continuous non-invasive measurement of MAP (MAPcNIAP) using a finger cuff. We explored the agreement of MAPcNIAP and MAPiNIAP with the gold standard: continuous invasive MAP ...
متن کاملNon-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery.
BACKGROUND This observational study was designed to evaluate the reliability and precision of a new digital photoplethysmographic device (Nexfin, BMEYE B.V., Amsterdam, The Netherlands) for continuous and non-invasive assessment of arterial pressure and cardiac output. METHODS Fifty consecutive adult subjects were prospectively enrolled at admission to the intensive care unit after convention...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 108 2 شماره
صفحات -
تاریخ انتشار 2012