TRiP98 is a treatment planning program for heavy ion radiotherapy[1] with a scanned ion beam and was developed at GSI[2]. It has been successfully used in clinical routine from 1997-2008 for over 400 patients, predominantly with head and neck tumors[3]. The treatment of mobile tumors, such as lung tumors, with a scanned ion beam poses additional challenges, resulting into a higher complexity of the treatment planning process[4]. In order to meet these additional requirements, new implementations for 4D treatment planning in TRiP98 were necessary and were first carried out by Bert et al.[4] However a large part of the treatment planning was done using the 3D functionality of TRiP98 in a combination with external software. To overcome the drawbacks of this solution new efforts are being made to extend TRiP98 for true 4D treatment planning in a fully integrated and flexible way. The status of these implementations is presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Status of 4D Treatment Planning Implementations for TRiP98

TRiP98 is a treatment planning program for radiotherapy with scanned ion beams. It was developed at GSI and has been successfully used in clinical routine from 1997-2008 for over 400 patients, predominantly with head and neck tumors [1,2]. The treatment of tumors within moving organs, such as lung tumors, with scanned ion beams involves additional complexity of the beam delivery and the treatme...

متن کامل

TRiP98: Parallelization of Dose Calculation

TRiP98, a treatment planning program, was used in the pilot project of heavy ion radiotherapy with scanned ion beams at GSI [1]. Over 400 patients were treated from 1997 to 2008 [2]. Currently TRiP98 is used for research purposes. One big part of the actual research is to make TRiP98 able to handle 4D data sets [3]. This is needed for the treatment of moving tumors (like lung tumors). Due to th...

متن کامل

Minimization-Algorithms for Biological Multiple Field Optimization

The software TRiP98 [1, 2, 3] is successfully used for patient treatment planning in the GSI pilot project. A crucial part of the treatment planning is the particle number optimization. The main goal of optimization is to achieve a target dose distribution as close as possible to the prescribed biological dose distribution. Multiple field optimization (MFO) allows a better target conformity and...

متن کامل

Experimental validation of survival calculations in the presence of motion

The software TRiP98 [1] is successfully used at GSI for treatment planning of stationary tumors. It is capable to calculate the absorbed dose and the biologically effective dose resulting from the superposition of usually several thousand C-12 pencil beams. Treatment is delivered with the raster scanner system [2]. If the target is subject to respiratory motion, treatment is not yet possible be...

متن کامل

Implementation of Beam Tracking and Dose Compensation in TRiP4D

Scanned particle beams are used since 1997 for treatment of stationary tumors [1]. One current field of research aims at transferring this highly tumor conformal treatment technique to moving tumors. Therefore, techniques to mitigate dose deteriorations caused by interference between beam scanning and tumor motion are needed [2]. Technical feasibility of different motion mitigation techniques h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010