[email protected] Establishment of a new lightning location system in Croatia

نویسندگان

  • I. UGLEŠIĆ
  • V. MILARDIĆ
  • B. FRANC
  • B. FILIPOVIĆ-GRČIĆ
  • J. HORVAT
چکیده

At the end of 2008, a new lightning location system (LLS) was established as part of LINET lightning detection network, which was developed in Germany and nowadays counts over 100 sensors installed across Europe. Four sensors were installed in different parts of Croatia. Together with sensors in neighbour countries, a sensor baseline of ≈250 km has been achieved covering Croatian territory. First data analysis show satisfactory detection efficiency (DE) and location accuracy (LA) with a statistical error less than 300 m. However, conducted analyses showed that network performance improvement is possible by installing two additional sensors. Software for real time lightning tracking with alarm function, analysis of lightning history, statistical calculations, correlation with power lines and creation of lightning density maps is being developed. Additional functionalities are in plan by connecting lightning data with SCADA, which enables a complete time and space correlation between lightning strikes and faults on transmission lines. Application of this software could provide as an effective decision making tool in control, maintenance and development of power systems. Paper shows examples of software application in power systems. Lightning data analysis for a period of one year are conducted in order to achieve a more comprehensive statistics. Analysis will show: number and ratio of lightning detected in Croatia distributed by type and polarity in different time periods; lightning current amplitude distribution; mean and average values of current amplitude and locating error.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Practical Examples Used Information and Communication Technologies in Study of “signals and Systems”

1 Karmela Aleksic-Maslac, University of Zagreb, Faculty of Electrical Engineering and Computing, Unska 3, Zagreb, Croatia, [email protected] 2 Branko Jeren, University of Zagreb, Faculty of Electrical Engineering and Computing, Zagreb, Croatia, [email protected] 3 Zvonko Kostanjcar (Student), University of Zagreb, Faculty of Electrical Engineering and Computing, Zagreb, Croatia, Zvonko.K...

متن کامل

Swarm-oriented mobile services: Step towards green communication

Green communication is a new focus within the telecommunications industry, leading to various innovative ideas how to optimize communication in order to achieve energy savings. While the majority of those ideas target the transport layer of communication systems, this paper takes a different approach and proposes an innovation for the application layer by introducing a novel concept in the mobi...

متن کامل

بررسی جامع اضافه‌ولتاژهای صاعقه در مزارع بادی با پیکربندی‌های متفاوت به همراه تاثیر سیستم زمین

This paper is treated with major risks applied by lightning strikes to wind farms. The risks illustrated in this research include overvoltage caused by direct and indirect effects of lightning strikes on any components of wind farm. As demands for electrical energy throughout our world is increased more and more nowadays, wind power plants are extended in every possible locations correspondingl...

متن کامل

In-line Typed High-Precision Polarization Lidar for Disaster Prevention

Prediction of local and steep weather change such as heavy rain and lightning strike are urgently needed for disaster prevention. In Japan, Automated Meteorological Data Acquisition System (AMeDAS) has been operational throughout the country, with a mesh size of 20 km. Lightning Location Positioning (LLP) system, Lightning Position and Tracking System (LPATS), and SAFIR (Surveillance et Alerte ...

متن کامل

Optimal reconfiguration of radial distribution system with the aim of reducing losses and improving voltage profiles using the improved lightning search algorithm

In this paper, a modified version of the lightning search algorithm is proposed in order to find the optimal reconfiguration of the switches and locate and determine the optimal capacity of distributed generation sources in the distribution feeder. The main optimization goals are to reduce ohmic losses and voltage deviations in the standard 33-bus and 94-node IEEE feeders. The simulation result...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010