Obesity does not influence prostate intrafractional motion
نویسندگان
چکیده
INTRODUCTION Motion of the prostate is problematic in the accurate delivery of external beam radiation therapy (EBRT) for prostate cancer. This study investigated the relationship between body mass index (BMI), an easily measured indicator of obesity, and prostate motion. METHODS Prostate motion during EBRT was assessed by measuring the displacement of fiducial markers implanted within the prostate in 130 prostate cancer patients. Interfractional motion was corrected on daily imaging through pre-treatment cone-beam-computed tomography (CBCT) and intrafractional motion measured using movie sequences captured using an electronic portal imaging device (EPID) during treatment delivery. RESULTS There was no statistically significant relationship between the mean intrafractional motion and BMI, except in the left-right (LR) translation (P = 0.049) over the study population. For each BMI category, there was no statistical significance (P > 0.05) between any of the translations/rotations except LR (P = 0.003). CONCLUSION While intrafractional motion is an important consideration, prostate motion cannot be reliably predicted through measurement of patient's BMI.
منابع مشابه
Intrafractional prostate motion during external beam radiotherapy monitored by a real‐time target localization system
This paper investigates the clinical significance of real-time monitoring of intrafractional prostate motion during external beam radiotherapy using a commercial 4D localization system. Intrafractional prostate motion was tracked during 8,660 treatment fractions for 236 patients. The following statistics were analyzed: 1) the percentage of fractions in which the prostate shifted 2-7 mm for a ce...
متن کاملIntrafractional Prostate Motion Management with the Clarity Autoscan System
Intrafractional motion of the prostate can be significant, and its management is of particular importance for hypofractionated regimes and stereotactic ablative radiotherapy (SABR). In this paper, we describe the Clarity Autoscan with Monitoring system and its use of non-invasive soft tissue imaging to monitor prostate motion during the course of radiotherapy. The system uses a 4D autoscan ultr...
متن کاملImpact of Intrafractional Prostate Motion on the Accuracy and Efficiency of Prostate Cancer Treatment on CyberKnife Radiotherapy
One of the most common treatments for men with localized prostate cancer is radiation therapy, which involves delivering small doses of radiation to the prostate for an extended period of time. Stereotactic-body radiation therapy (SBRT) is a form of radiotherapy that delivers increased dosage to the prostate with more precision. The results are shorter treatment times, increased effectiveness, ...
متن کاملAssessment of MLC tracking performance during hypofractionated prostate radiotherapy using real-time dose reconstruction
By adapting to the actual patient anatomy during treatment, tracked multi-leaf collimator (MLC) treatment deliveries offer an opportunity for margin reduction and healthy tissue sparing. This is assumed to be especially relevant for hypofractionated protocols in which intrafractional motion does not easily average out. In order to confidently deliver tracked treatments with potentially reduced ...
متن کاملQuantifying variability of intrafractional target motion in stereotactic body radiotherapy for lung cancers
In lung stereotactic body radiotherapy (SBRT), variability of intrafractional target motion can negate the potential benefits of four-dimensional (4D) treatment planning that aims to account for the dosimetric impacts of organ motion. This study used tumor motion data obtained from CyberKnife SBRT treatments to quantify the reproducibility of probability motion function (pmf) of 37 lung tumors....