Determination of Platelet and White Blood Cell Counts from Peripheral Blood Smear: An Indispensable Method in Under-resourced Laboratories

نویسندگان

  • Imoru Momodu
  • Galya Ivanova
چکیده

Objective: Blood smear examination serves as a quality control tool in verifying the results generated by the automated analyzer and identification of abnormal or immature cells amongst other functions. This study was undertaken to estimate platelet and White Blood Cell (WBC) counts from Peripheral Blood Smear (PBS) and to correlate them with the results from automated method. Materials and Methods: Fifty blood samples collected into K3 EDTA from 30 males and 20 females whose ages were from 2 to 50 years, and attended General Out-Patient Department (GOPD) of Aminu Kano Teaching Hospital, Kano between May and November, 2015 were considered for the study. Each blood sample was used for the determination of full blood count using Swelab Alfa hematology analyzer, and preparation of stained blood films using standard laboratory methods. Results: There were significantly lower values of platelet count (using multiplication factor of 15.0 x10/L) and white blood cell count (using multiplication factor of 2.0 x10/L) to derive (22.42±60.77) x10/L and (4.49±1.04) x10/L by manual (PBS) method as compared to (267.86±77.28) x 10/L and (5.86±1.36) x10/L respectively, for automated method (P<0.001). However, there was no Original Research Article Momodu; IBRR, 5(2): 1-7, 2016; Article no.IBRR.25105 2 significant difference in estimated platelet count by manual (PBS) method using multiplication factor of 20.0 x10/L compared to automated method (P>0.05). Fairly strong positive correlations were observed for platelet and white blood cell counts when manual method was compared to automated method (r= 0.6828 0.7321, P<0.05). Conclusion: It can be concluded that multiplications factors of 20.0 x10/L per 100X, objective lens and 2.7 x10/L per 40X, objective lens can be used for average numbers of platelets and white blood cells respectively to estimate platelet and white blood cell counts from PBS as the results are comparable to that of the hematology analyzer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of platelet count in unstained peripheral blood smears in comparison with stained smears and evaluation of its efficacy.

Assessment of platelet count is an important diagnostic parameter in haematology. Automated blood cell counters have largely replaced the manual method. However, all abnormal platelet counts are verified in Leishman's stained peripheral blood smear. Platelets also can be identified in the unstained blood smears. The objective of this study is to compare the unstained peripheral blood smears wit...

متن کامل

آگلوتینین سرد پلاکتی، پدیده ای نادر و در عین حال مهم در آزمایشگاه: گزارش یک مورد ترومبوسیتوپنی کاذب در یک بیمار مبتلا به سرطان کولون

Background: Cold antibody induced platelet clumping is a rare in-vitro phenomenon that causes EDTA independent pseudo thrombocytopenia. This pre-analytical problem leads to a challenge in the clinical laboratory. In such a case platelets tend to easily aggregate in vitro, giving rise to lower platelet counts. The error is detected simply by examining peripheral blood smear. This report describe...

متن کامل

Elevated white blood cell counts and risk of metabolic syndrome: a dose-response meta-analysis

Background and Aim: Elevated white blood cell count has been a known risk factor for cardiovascular diseases. Cardiometabolic diseases have some risk factors in common. Therefore, we assessed the association between elevated white blood cell counts and risk of metabolic syndrome using dose-response meta-analysis method. Materials & Methods: We searched for observational studies including white ...

متن کامل

Study on the kinetics and influence of feline platelet aggregation and deaggregation.

BACKGROUND Feline platelets are prone to clumping after blood collection, rendering the determination of accurate platelet counts difficult for clinical laboratories and resulting in a high incidence of pseudothrombocytopenia in feline haematology reports. No information is available about the kinetics of platelet aggregate formation in feline ethylenediaminetetraacetic acid blood and the cours...

متن کامل

بررسی اثر گازهای شیمیایی(به طور عمده موستارد) روی نوتروفیل‌های مصدومان شیمیایی 10 سال پس از مصدومیت طی جنگ تحمیلی

The incidence of recurrent infections in chemical injuries made us guess that phagocytic system of these patients has been disordered. On the other hand, deficiency of phagocytic function in scalds has been proved and superficial burns seen in these subjects also encouraged us to study the condition of their neutrophils. Neutrophils are one of the main members of natural immunity an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016