An insight into the phenomena involved in a multiple-function stationary phase for the capillary electrochromatographic separation of 2'-, 3'-, and 5'-monophosphorylated nucleoside isomers.

نویسندگان

  • Shu-Yu Lin
  • Chuen-Ying Liu
چکیده

The electrochromatographic separations of 2'-, 3'- and 5'-monophosphates of adenosine, guanosine, cytidine, and uridine were carried out with an open-tubular capillary column which was wall-coated with a highly selective reagent, 28-membered macrocyclic polyamine, 4, 8, 12, 18, 22, 26-hexaaza-1,15-dioxacyclooctaeicosane ([28]ane-N6O2). The effects of pH, composition and concentration of background electrolyte (BGE), applied voltage, column length, and the additive of the BGE, such as metal ions, borate, beta-cyclodextrin and organic solvent on the separation of these monophosphorylated nucleotide isomers were investigated. The results suggested that the interactions between analytes and the bonded groups on the wall predominantly comprise anion coordination and anion exchange in addition to the electrophoresis. A well-resolved electrochromatogram was obtained with the capillary column of 100 cm (75 cm effective length) x 75 microm inside diameter (ID), citrate buffer (20 mM, pH 3.99), applied voltage of -22 kV and detection at 254 nm. Column efficiency was found with the average theoretical plate numbers of 119,500/m and a low detection limit of 0.01 microM level could be achieved for the separation of these isomers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capillary electrochromatographic evaluation of vitamin E-active oil constituents: tocopherols and tocotrienols.

Separations of lipid antioxidants, tocopherols (T) and tocotrienols (T3), on octylsilica (OS), octadecylsilica (ODS), phenylsilica, or silica were studied by capillary electrochromatography (CEC)-UV detection. The homologues and isomers of the vitamin E-active compounds were best separated with an OS column. CEC with an ODS column tended to yield broad peaks with poor resolution. Among the vari...

متن کامل

Preparation and evaluation of rigid porous polyacrylamide-based strong cation-exchange monolithic columns for capillary electrochromatography.

A CEC monolithic column with strong cation-exchange (SCX) stationary phase based on hydrophilic monomers was prepared by in situ polymerization of acrylamide, methylenebisacrylamide, and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) in a complete organic binary porogenic solvent consisting of DMSO and dodecanol. The sulfonic groups provided by the monomer AMPS on the surface of the statio...

متن کامل

Polar stationary phases for capillary electrochromatography.

This review article summarizes the variety of polar stationary phases that have been employed for capillary electrochromatographic separations. Compared with reversed-phase stationary phases, the polar alternatives provide a completely different retention selectivity towards polar and charged analytes. Different types of polar stationary phases are reviewed, including the possible retention mec...

متن کامل

Preparation of a positively charged cellulose derivative chiral stationary phase with copolymerization reaction for capillary electrochromatographic separation of enantiomers.

A positively charged chiral stationary phase (CSP) was prepared by chemically immobilizing cellulose 3,5-dimethylphenylcarbamate onto methacryloyldiethylenetriaminopropylated silica (MCDEAPS) via a radical copolymerization reaction. The prepared CSP was evaluated for enantiomer separation in nonaqueous capillary electrochromatography (CEC). Electroosmotic flow (EOF) generated on the prepared CS...

متن کامل

Capillary electrochromatographic separation of enantiomers under aqueous mobile phases on a covalently bonded cellulose derivative chiral stationary phase.

A chemically bonded cellulose tris(3,5-dimethylphenylcarbamate) chiral stationary phase (CSP) was prepared by a radical polymerization reaction. The prepared CSP was packed into fused-silica capillaries with inner diameter of 75 microm to perform enantiomer separations in CEC. The electrochromatographic behavior of the CSP was investigated. On the prepared CSP, high EOF could be generated under...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Electrophoresis

دوره 24 17  شماره 

صفحات  -

تاریخ انتشار 2003