Membrane inlet mass spectrometry for homeland security and forensic applications.

نویسندگان

  • Stamatios Giannoukos
  • Boris Brkić
  • Stephen Taylor
  • Neil France
چکیده

A man-portable membrane inlet mass spectrometer has been built and tested to detect and monitor characteristic odors emitted from the human body and also from threat substances. In each case, a heated membrane sampling probe was used. During human scent monitoring experiments, data were obtained for inorganic gases and volatile organic compounds emitted from human breath and sweat in a confined space. Volatile emissions were detected from the human body at low ppb concentrations. Experiments with compounds associated with narcotics, explosives, and chemical warfare agents were conducted for a range of membrane types. Test compounds included methyl benzoate (odor signature of cocaine), piperidine (precursor in clandestine phencyclidine manufacturing processes), 2-nitrotoluene (breakdown product of TNT), cyclohexanone (volatile signature of plastic explosives), dimethyl methylphosphonate (used in sarin and soman nerve agent production), and 2-chloroethyl ethyl sulfide (simulant compound for sulfur mustard gas). Gas phase calibration experiments were performed allowing sub-ppb LOD to be established. The results showed excellent linearity versus concentration and rapid membrane response times.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FOCUS: HARSH ENVIRONMENT MASS SPECTROMETRY Application of Membrane Inlet Mass Spectrometry for Online and In Situ Analysis of Methane in Aquatic Environments

A method is presented for the online measurement of methane in aquatic environments by application of membrane inlet mass spectrometry (MIMS). For this purpose, the underwater mass spectrometer Inspectr200-200 was applied. A simple and reliable volumetric calibration technique, based on the mixing of two end member concentrations, was used for the analysis of CH4 by MIMS. To minimize interferen...

متن کامل

Forensic and homeland security applications of modern portable Raman spectroscopy.

Modern detection and identification of chemical and biological hazards within the forensic and homeland security contexts may well require conducting the analysis in field while adapting a non-contact approach to the hazard. Technological achievements on both surface and resonance enhancement Raman scattering re-developed Raman spectroscopy to become the most adaptable spectroscopy technique fo...

متن کامل

Application of membrane inlet mass spectrometry for online and in situ analysis of methane in aquatic environments.

A method is presented for the online measurement of methane in aquatic environments by application of membrane inlet mass spectrometry (MIMS). For this purpose, the underwater mass spectrometer Inspectr200-200 was applied. A simple and reliable volumetric calibration technique, based on the mixing of two end member concentrations, was used for the analysis of CH(4) by MIMS. To minimize interfer...

متن کامل

Rapid Analysis of Trace Drugs and Metabolites Using a Thermal Desorption DART-MS Configuration.

The need to analyze trace narcotic samples rapidly for screening or confirmatory purposes is of increasing interest to the forensic, homeland security, and criminal justice sectors. This work presents a novel method for the detection and quantification of trace drugs and metabolites off of a swipe material using a thermal desorption direct analysis in real time mass spectrometry (TD-DART-MS) co...

متن کامل

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

The advantages of mass spectrometry (MS) in combination with gas chromatography (GC) – in terms of providing both qualitative and quantitative information are well known. However, confident identification and accurate measurement of trace toxic and odorous species at the lowest levels of interest may be compromised by chromatographic anomalies such as; column bleed, extended solvent tails, air ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society for Mass Spectrometry

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 2015