Evaluation of Elbow Stretch Reflex Using a Portable Hand-driven Isokinetic System in Normal Adults

نویسندگان

  • Jeong-Hwan Seo
  • Soon-Won Yook
  • Chul-Gyu Song
  • Myoung-Hwan Ko
  • Sung-Hee Park
چکیده

OBJECTIVE To evaluate normal healthy persons without spasticity to observe normal findings of the elbow stretch reflex using a newly developed, portable, hand-driven spasticity-measuring system. METHOD Thirty normal persons without any disease involving the central or peripheral nervous system were enrolled in this study. The portable hand-driven isokinetic system is able to measure the joint angle, angular velocity, electromyographic (EMG) signals, and torque during elbow passive extension-flexion. One set of 10 passive elbow extension and flexion movements was performed for data acquisition at each angular velocity, including 60, 90, 120, 150 and 180 degrees per second (°/sec). Electromyographic data were collected from the biceps brachii and the triceps brachii. Torque data were collected from sensors around the wrist. RESULTS We were able to detect EMG activity and torque in all subjects by using the new portable hand-driven isokinetic system. EMG activity and torque increased with incremental increase of angular velocities. The joint angle of maximal EMG activity according to different angular velocities did not show any significant difference (116°-127° in elbow extension and 37°-66° in elbow flexion). The joint angles of maximal torque according to different angular velocities were not significantly different either. CONCLUSION Using the portable hand-driven isokinetic system on the elbows of normal subjects, we were able to obtain expected results. By considering our normal findings of the elbow stretch reflex using this system, we propose that the various aspects of spasticity-related data can be measured successfully.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of portable muscle tone measurement device for quantifying velocity-dependent properties in elbow spasticity.

The objective of this study is to develop a portable device for quantifying the velocity-dependent properties of spastic elbow muscles. Based on a motor-driven system, validation tests of the portable system such as accuracy and response of sensors were first examined. Furthermore, simulated modules (inertia, damper and spring) as well as elbow joints (15 control and 15 hemiplegic subjects) wer...

متن کامل

Validation of Portable Muscle Tone Measurement Device Based on a Motor-driven System

As a component of upper motor neuron syndrome, assessment of abnormality in muscle tone, including spasticity and rigidity, is a routine clinical examination. The aim of this study is to extend a sophisticated motor-driven measurement system, developed in our previous research, as a validation platform for developing a portable muscle tone measurement system. The main features of hand-held musc...

متن کامل

Effect of contraction level and magnitude of stretch on tonic stretch reflex transmission characteristics.

Electromyogram tonic stretch reflex responses were recorded from biceps brachii muscles in normal and cerebral palsied subjects sustaining either 10% or 20% of maximum voluntary contraction and attempting to keep the elbow stiff in a fixed position. The muscle was stretch by a sinusoidal perturbation applied by the experimenter to the elbow angle. Five different amplitudes of stretch were emplo...

متن کامل

Acute Whole-Body Vibration does not Facilitate Peak Torque and Stretch Reflex in Healthy Adults.

The acute effect of whole-body vibration (WBV) training may enhance muscular performance via neural potentiation of the stretch reflex. The purpose of this study was to investigate if acute WBV exposure affects the stretch induced knee jerk reflex [onset latency and electromechanical delay (EMD)] and the isokinetic knee extensor peak torque performance. Twenty-two subjects were randomly assigne...

متن کامل

Evolution of Quantitative Approaches for Muscle Spasticity Measurement

About 20 years ago, I first joined the spasticity measurement research group at biosignal laboratory (leaded by Dr. Jia-Jin Jason Chen) of Institute of Biomedical Engineering, National Cheng Kung University. At that time, the limitation of clinical approach for spasticity evaluation was initially noted by the researchers [1]. We developed our first quantitative measurement system based on drive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2011