Siphon effects on continuous subcutaneous insulin infusion pump delivery performance.
نویسندگان
چکیده
BACKGROUND The objective was to quantify hydrostatic effects on continuous subcutaneous insulin infusion (CSII) pumps during basal and bolus insulin delivery. METHODS We tested CSII pumps from Medtronic Diabetes (MiniMed 512 and 515), Smiths Medical (Deltec Cozmo 1700), and Insulet (OmniPod) using insulin aspart (Novolog, Novo Nordisk). Pumps were filled and primed per manufacturer's instructions. The fluid level change was measured using an inline graduated glass pipette (100 microl) when the pipette was moved in relation to the pump (80 cm Cosmo and 110 cm Medtronics) and when level. Pumps were compared during 1 and 5 U boluses and basal insulin delivery of 1.0 and 1.5 U/h. RESULTS Pronounced differences were seen during basal delivery in pumps using 80-100 cm tubing. For the 1 U/h rate, differences ranged from 74.5% of the expected delivery when the pumps were below the pipettes and pumping upward to 123.3% when the pumps were above the pipettes and pumping downward. For the 1.5 U/h rate, differences ranged from 86.7% to 117.0% when the pumps were below or above the pipettes, respectively. Compared to pumps with tubing, OmniPod performed with significantly less variation in insulin delivery. CONCLUSIONS Changing position of a conventional CSII pump in relation to its tubing results in significant changes in insulin delivery. The siphon effect in the tubing may affect the accuracy of insulin delivery, especially during low basal rates. This effect has been reported when syringe pumps were moved in relation to infusion sites but has not been reported with CSII pumps.
منابع مشابه
Comparing Effects of Continuous Insulin Infusion with or without Subcutaneous Glargine Insulin on Glycemic Control in Diabetic Patients Undergoing Coronary Artery Bypass Graft (CABG)
OBJECTIVE: Hyperglycemia is associated with increased morbidity and mortality in diabetic patients following coronary artery bypass grafting. Tight glycemic control in perioperative period can reduce these events. The goal of this study was to determine whether combination of continuous infusion and subcutaneous glargine as a basal insulin could improve glycemic control. MATERIAL AND METHODS:...
متن کاملEffects of pulsatile subcutaneous injections of insulin lispro on plasma insulin concentration levels.
BACKGROUND Most insulin pumps used for the treatment of diabetes perform subcutaneous insulin injections by pulses. The purpose of this work is to analyze the effects of pulsatile injections of modern insulins on plasma insulin levels compared with a continuous insulin infusion. METHOD We simulate pulsatile implementations of a basal rate profile over a day on a type 1 diabetes mellitus patie...
متن کاملPatient reactions to long-term outpatient treatment with continuous subcutaneous insulin infusion.
Fourteen of the first 15 insulin-dependent diabetics to be treated in our unit by three weeks or more of outpatient continuous subcutaneous insulin infusion with a portable syringe pump completed a questionnaire about their reactions to the system. Motivation was more important to a favourable response than occupation or intelligence. Most patients thought that diabetic control was better with ...
متن کاملAn experimental study of pulsed micro-flows pertinent to continuous subcutaneous insulin infusion therapy
An experimental study was conducted to investigate the unsteady micro-flow driven by an insulin pump commonly used in continuous subcutaneous insulin infusion (CSII) therapy. A microscopic particle image velocimetry (PIV) system was used to characterize the transient behavior of the micro-flow upon the pulsed excitation of the insulin pump in order to elucidate the underlying physics for a bett...
متن کاملImpairment of Continuous Insulin Delivery Therapy and Analysis from Graeco-Latin Square Design Model
The desire to deliver measured amount of insulin continuously to patients with type I diabetes, for glycemic control, has attracted a lot of attention. Continuous subcutaneous insulin infusion has seen some success in recent years. However, occlusion of insulin delivery may prevent the patient from receiving the prescribed dosage, with adverse consequence. An in vitro study of insulin delivery ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of diabetes science and technology
دوره 4 1 شماره
صفحات -
تاریخ انتشار 2010