Double-lumen tube intubation using video laryngoscopy causes a milder cardiovascular response compared to classic direct laryngoscopy

نویسندگان

  • Wei Wei
  • Ming Tian
چکیده

OBJECTIVE To determine whether there is a clinically relevant difference between the circulatory responses to double-lumen tube intubation (DLTI) with the GlideScope video laryngoscope versus the Macintosh direct laryngoscope. METHODS Eighty adult patients requiring double-lumen tubes for thoracic surgery were randomly and equally allocated to either a Macintosh direct laryngoscope group (DL group, n = 40) or a Glide Scope video laryngoscope group (GS group, n = 40). DLTI was performed after airway evaluations and induction of anesthesia. Systolic blood pressure (SBP) and heart rate (HR) were recorded before induction (baseline values), immediately before intubation (post-induction values), at intubation and after intubation. Rate-pressure-product (RPP), and the areas under SBP- and HR-time curves were calculated. All data obtained by the two devices were compared. RESULTS After laryngoscope insertion, SBP of DL and GS groups changed significantly differently (13.1% vs. 4.6%, P< 0.001), while HR changed similarly (17.2% vs. 14.6%, P = 0.074). One minute after intubation, both SBP and HR significantly increased in both groups (SBP: 11.6% vs. 11.9%; HR: 18.4% vs. 10.8%), but there were no significant differences between the two groups. RPP significantly increased in both groups after laryngoscope insertion (32.6%, P=0.001; 18.2%, P=0.002), and there was a significant difference between the two groups (P =0.001). Throughout intubation, the areas under SBP-time curves had a significant difference between the two groups (P = 0.042), while those under HR-time curves did not differ significantly (P=0.06). CONCLUSION The intubation response was most significant upon laryngoscope insertion during the whole intubation process. The GlideScope video laryngoscope induced milder circulatory fluctuations than the Macintosh direct laryngoscope did, suggesting that DLTI using video laryngoscopy can help reduce the cardiovascular response to intubation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of hemodynamic changes in patients using conventional laryngoscopy and video laryngoscope in surgery

Introduction: One of the complications of laryngoscopy and endotracheal intubation is sympathetic stimulation with hemodynamic changes that are always tried to be avoided by anesthesiologists. The aim of this study is to review and compare hemodynamic changes caused by both conventional and video laryngoscopy. Methods: In this clinical trial performed in 2015 in the Birjand-based Imam Reza Hosp...

متن کامل

Haemodynamic response at double lumen bronchial tube placement - Airtraq vs. MacIntosh laryngoscope, a randomised controlled trial

INTRODUCTION Tracheal intubation causes a haemodynamic response that might be harmful for patients. The Airtraq® laryngoscope has been shown to decrease the haemodynamic response to single-lumen tube intubation. We hypothesised that double-lumen bronchial tube placement with the Double-lumen Airtraq® laryngoscope would cause a reduced haemodynamic response and decreased catecholamine release co...

متن کامل

Cardiovascular changes after the three stages of nasotracheal intubation.

BACKGROUND Nasotracheal intubation typically comprises three distinct stages: (i) nasopharyngeal intubation; (ii) direct laryngoscopy to identify the vocal cords; and (iii) the passage of the tracheal tube into the trachea. The aim of this study was to identify and compare the cardiovascular responses associated with each of these stages. METHODS Seventy-five ASA I or II patients, aged 16-65 ...

متن کامل

مقایسه‌ی عوارض قلبی عروقی لارنگوسکوپی مستقیم و ویدئولارنگوسکوپی در افراد بالای 65 سال

Background and Objective: Laryngoscopy and tracheal intubation can be achieved through both direct and video laryngoscopy. As video laryngoscopy complications still remain unknown among the elderly, this study was emerged to grasp the idea on the complications of two aforementioned methods among the elderly. Materials and Methods: In this clinical trial study, 60 patients over 65 years who h...

متن کامل

Hemodynamic and Humoral Response to Intubation with Double-lumen Endotracheal Tubes Versus Single-lumen Tubes Combined with an Endobronchial Blocker: A Randomized Clinical Trial

Introduction: Insertion of endotracheal tubes, especially large and relatively inflexible double-lumen tubes, provokes cardiovascular and humoral responses which can cause complications. Bronchial blockers, combined with conventional single-lumen tubes (SLT), serve as alternatives to double-lumen tubes (DLT) and may provoke less hemodynamic response. Methods: Forty adults scheduled for elective...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2016