Fluorescence of Dyes in Solutions with High Absorbance. Inner Filter Effect Correction
نویسندگان
چکیده
Fluorescence is a proven tool in all fields of knowledge, including biology and medicine. A significant obstacle in its use is the nonlinearity of the dependence of the fluorescence intensity on fluorophore concentration that is caused by the so-called primary inner filter effect. The existing methods for correcting the fluorescence intensity are hard to implement in practice; thus, it is generally considered best to use dilute solutions. We showed that correction must be performed always. Furthermore, high-concentration solutions (high absorbance) are inherent condition in studying of the photophysical properties of fluorescent dyes and the functionally significant interactions of biological macromolecules. We proposed an easy to use method to correct the experimentally recorded total fluorescence intensity and showed that informative component of fluorescence intensity numerically equals to the product of the absorbance and the fluorescence quantum yield of the object. It is shown that if dye molecules do not interact with each other and there is no reabsorption (as for NATA) and spectrofluorimeter provides the proportionality of the detected fluorescence intensity to the part of the absorbed light (that is possible for spectrofluorimeter with horizontal slits) then the dependence of experimentally detected total fluorescence intensity of the dye on its absorbance coincides with the calculated dependence and the correction factor for eliminating the primary inner filter effect can be calculated on the basis of solution absorbance. It was experimentally shown for NATA fluorescence in the wide range of absorbance (at least up to 60). For ATTO-425, which fluorescence and absorption spectra overlap, the elimination of the primary and secondary filter effects and additional spectral analysis allow to conclude that the most probable reason of the deviation of experimentally detected fluorescence intensity dependence on solution absorbance from the calculated dependence is the dye molecules self-quenching, which accompanies resonance radiationless excitation energy transfer.
منابع مشابه
Inner Filter Effect in the Fluorescence Emission Spectra of Room Temperature Ionic Liquids with-β-Carotene
Steady-state fluorescence spectroscopy is highly sensitive an analytical fluorescence detecting tool limited to diluted samples. The serious problem of quantitative analysis is dominant in the samples with optical density higher than 0.05 (10 mm cell) detected in the right angle cell geometry, because of the two kinds of inner filter effects IFEs (Lakowicz, 2006; Li & Hu, 2007; Kao et al., 1998...
متن کاملExcitation energy transfer and trapping in dye-loaded solid particles.
The photophysics of several systems composed of a single dye or pairs of dyes attached to solid particles has been studied in the dry solid state at high dye concentrations taking into account light scattering and inner filter effects. Interaction among dye molecules and singlet-singlet energy transfer are relevant in these conditions, as has been demonstrated for pairs of dyes with suitable sp...
متن کاملSimultaneous Spectrophotometric Determination of Heavy Metal Ions Using Several Chemometrics Methods: Effect of Different Parameters of Savitzky-Golay and Direct Orthogonal Signal Correction Filters
Direct orthogonal signal correction(DOSC) and Savitzky-Golay filters (SGF) were applied as preprocessing methods on the original and first derivative absorbance data. Principle component regression (PCR), partial least squares (PLS) and iterative target transformation factor analysis (ITTFA), were used in spectrophotometric simultaneous determination of heavy divalent metal ions, l...
متن کاملHomogeneous fluorescence-based immunoassay via inner filter effect of gold nanoparticles on fluorescence of CdTe quantum dots.
Homogeneous immunoassays are becoming more and more attractive for modern medical diagnosis because they are superior to heterogeneous immunoassays in sample and reagent consumption, analysis time, portability and disposability. Herein, a universal platform for homogeneous immunoassay, using human immunoglobulin (IgG) as a model analyte, has been developed. This assay relies upon the inner filt...
متن کاملDimethyl sulfoxide, diethyl fumarate solution for high dose dosimetry
Background: Dosimetry is a fundamental part of the radiation processing industry. Aqueous inorganic dosimeters have been used for gamma radiation dosimetry such as standard ferrous sulfate dosimeter. The purpose of this study was to investigate the effect of gamma radiation on the diethyl fumarate DEF in dimethyl sulfoxide DMSO solution and its possible use in chemical dosimetry. Materials and ...
متن کامل