A novel method of accurately calculating the radiological magnification of the hip.
نویسندگان
چکیده
We have developed a novel method of calculating the radiological magnification of the hip using two separate radio-opaque markers. We recruited 74 patients undergoing radiological assessment following total hip replacement. Both the new double marker and a conventional single marker were used by the radiographer at the time of x-ray. The predicted magnification according to each marker was calculated, as was the true radiological magnification of the components. The correlation between true and predicted magnification was good using the double marker (r = 0.90, n = 74, p < 0.001), but only moderate for the single marker (r = 0.50, n = 63, p < 0.001). The median error was significantly less for the double marker than for the single (1.1% vs 4.8%, p < 0.001). The double marker method demonstrated excellent validity (intraclass correlation coefficient = 0.89), in contrast to the single marker (0.32). The double marker method appears to be superior to the single marker method when used in the clinical environment.
منابع مشابه
Digital templating in hip replacement with and without radiological markers.
Digital templating in hip replacement is commonly performed with radiological markers to determine the magnification. The latter can also be determined by measuring the distance from the x-ray focal spot to the object and the distance from the x-ray focal spot to the radiological cassette or image receptor. We used post-operative radiographs of total hip replacements and hemiarthroplasties from...
متن کاملA New Digital Preoperative Planning Method for Total Hip Arthroplasties
Preoperative templating is an important part of a THA. The ability to accurately determine magnification of the hip on the radiograph and apply identical magnification to the radiograph and template will improve accuracy of preoperative templating of THA. We designed a templating method using a new way of determining the hip magnification with a linear relationship between magnification of the ...
متن کاملComparing the Accuracy of Waist-Hip Ratio Calculation by the BIA device versus the Manual Method
Nowadays, the Waist-Hip Ratio is considered one of the most important indices in predicting the risk of cardiovascular diseases. The usual method for calculating this index is by measuring the waist and hip circumferences with a measuring tape. However, bioelectrical impedance analysis (BIA) devices are also capable of calculating this ratio. Hence, the goal of this study was to calculate this ...
متن کاملReparative radiological changes of hip joint after TNF inhibitors in ankylosing spondylitis
Background: Hip involvement in ankylosing spondylitis (AS) is a common extraspinal arthritic manifestation, which is associated to a worse functional outcome. Little data are available on the effectiveness of conservative treatment strategies. The TNF inhibitors have been proven effective on AS activity parameters. Their structural effect on hip disease however, little is studied. Case pres...
متن کاملCalculating cost efficiency using prices dependent on time via approximate method
In the traditional cost-efficiency model, the information about each decision unit includes inputs, outputs, and the input prices are fixed and specific. In practice, the price of the inputs often fluctuates at different times, and these prices for the decision-making unit are time-dependent. By the traditional method, the efficiency of decision units is impossible in the presence of time-depen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 91 9 شماره
صفحات -
تاریخ انتشار 2009