SKML-Quality Mark for point-of-care test (POCT) glucose meters and glucose meters for home-use.

نویسندگان

  • Rob T P Jansen
  • Robbert J Slingerland
چکیده

BACKGROUND Point-of-care glucose meters are used increasingly in semi- and non-professional context. The quality of glucose measurements depends on the quality of the equipment, the quality of use, and the pre-analytical conditions. In this article, a External Quality Assessment Scheme (SKML)-Quality Mark for point-of-care test (POCT) and self-test glucose meters is proposed, assessing analytical quality and technical quality. The analytical requirements are based on the biological variation concept, and a system to assess meters for the SKML-Quality Mark is described. Using the proposed system as an example, 14 meters were tested. METHODS The analytical quality of the POCT and self-test equipment was assessed for plasma calibrated glucose values by comparison with a trueness verified method traceable to the IFCC reference method in an accredited clinical laboratory. The concept is based on the biological variation system. The SKML-Quality Mark comprises the following criteria for blood glucose equipment: 1) Fulfilment of compliance with ISO 15197 and/or TNO guideline criterion; 2) Fulfilment of the total allowable error (TAE) criterion; 3) Fulfilment of the total allowable linearity bias criterion; 4) Fulfilment of the total allowable interfering substances bias criterion; and 5) Fulfilment of the haematocrit criterion. RESULTS The proposed SKML-Quality Mark system was tested on 14 commercial home-use meters. The TAE criterion is violated by two meters. The main reason for the violation is bias. For the majority of meters, the Passing and Bablok regression confidence interval does not include the intercept of 0.0 and slope of 1.0. In addition, Syx indicates dispersion around the line or non-linearity. The bias and total error at three different concentrations were investigated as part of the quality mark, resulting in disapproval of the Dicomed Sensocard Plus meter. The bias was significant for the Wellion Linus. With respect to interfering substances, bias of the same magnitude and sign as the bias without additive was seen for all meters for acetaminophen, indicating no additional interference. For ascorbic acid, an additional bias was seen for several meters. However, significant bias was demonstrated for the Sensocard Plus and Glucocard X-meter. CONCLUSIONS The biological variation concept offers a scientific basis for assessment of acceptable deviation. The concept is extended in the SKML-Quality Mark correcting for the limited number of measurements that can be performed while assessing home-use or POCT meters. The results show that three out of 14 meters fail the proposed quality mark.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The application of glucose point of care testing in three metropolitan hospitals.

The application of glucose point of care testing (PoCT) in hospitals has been a contentious subject for many years. No information is available regarding the extent to which glucose PoCT is used within the Australian hospital system and whether such testing is fit for its intended purpose. The aim of this study was to investigate the extent to which glucose PoCT is used within three teaching ho...

متن کامل

Glucose meters - fit for clinical purpose.

Glucose meters have improved considerably since they were first introduced in 1960, but many questions are being asked about their accuracy and reliability in certain clinical situations. These questions have arisen because of the widespread use of these meters into clinical areas they have not been designed for such as critical care. The lack of understanding by some health professionals on fa...

متن کامل

Glucose Meter Use in the Intensive Care Unit: Much Ado About Something

Glucose meters are a fast and convenient way to measure circulating blood glucose. Like many technologies in healthcare, the use of glucose meters within the hospital has evolved significantly over the last few decades. This change has been driven predominantly by changes in the approach to glycemic control for critically ill patients. Both glycemic control in the intensive care unit (ICU), and...

متن کامل

Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs

Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...

متن کامل

ASVCP guidelines: quality assurance for portable blood glucose meter (glucometer) use in veterinary medicine.

Portable blood glucose meters (PBGM, glucometers) are a convenient, cost effective, and quick means to assess patient blood glucose concentration. The number of commercially available PBGM is constantly increasing, making it challenging to determine whether certain glucometers may have benefits over others for veterinary testing. The challenge in selection of an appropriate glucometer from a qu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 48 7  شماره 

صفحات  -

تاریخ انتشار 2010