Highly sensitive detection of monosaccharides on microchip electrophoresis using pH discontinuous solution system.

نویسندگان

  • Hideya Nagata
  • Tamitake Itoh
  • Yoshinobu Baba
  • Mitsuru Ishikawa
چکیده

We improved the detection sensitivity of neutral and amino monosaccharides labeled with 2-aminoacridone by a factor of 19.6-48.7 and 44.4-65.9, respectively, with no deterioration in separation resolution, using a pH discontinuous solution system instead of the conventional solution system. The pH discontinuous solution system is simple, using only a borate solution at pH 6.0 as a sample solution and a Tris-borate solution at pH 9.3 as a separation solution, enabling an enhancement of the sensitivity by monosaccharide stacking. This technique is fully compatible with conventional microchip electrophoresis, thereby allowing us to develop efficient tools for highly sensitive and resolved detection of monosaccharides.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Protein Separation by Microchip Electrophoresis Using Quartz Chip

Electrophoretic separation techniques using microchips have been dramatically improved and several commercial MCE systems have been developed. For example, the Agilent Technologies 2100 Bioanalyzer system is commercially available with a protein separation chip and reagent kit that enables rapid and highly efficient protein separation based on their molecular size [1]. Separation of protein mix...

متن کامل

Detection of miRNA in Cell Cultures by Using Microchip Electrophoresis with a Fluorescence-Labeled Riboprobe

The analysis of a microRNA (miRNA), miR-222 isolated from the PC12 cell line, was performed by use of the ribonuclease (RNase) protection assay, cyanine 5 (Cy5)-labeled miR-222 riboprobe, and a Hitachi SV1210 microchip electrophoresis system, which can be used to evaluate the integrity of total RNA. The fluorescence intensity corresponding to the protected RNA fragment increased in a dose-depen...

متن کامل

Rapid separation of microorganisms by quartz microchip capillary electrophoresis.

We developed and optimized a system coupling microchip capillary electrophoresis (MCE) and laser-induced fluorescence (LIF) detection for the analysis of microorganisms. The MCE-LIF system successfully separated pure cultures of lactic acid bacteria and Saccharomyces cerevisiae within 200 s. The results indicate that the MCE system can be conveniently used for the rapid and highly sensitive det...

متن کامل

Three-electrode electrochemical detector and platinum film decoupler integrated with a capillary electrophoresis microchip for amperometric detection.

This article demonstrates that a three-electrode electrochemical (EC) detector and an electric decoupler could be fabricated in the same glass chip and integrated with an O2-plasma-treated PDMS layer using microfabrication techniques to form the capillary electrophoresis (CE) microchip. The platinized decoupler could mostly decouple the electrochemical detection circuit from the interference of...

متن کامل

Contactless conductivity detector for microchip capillary electrophoresis.

A microfabricated electrophoresis chip with an integrated contactless conductivity detection system is described. The new contactless conductivity microchip detector is based on placing two planar sensing aluminum film electrodes on the outer side of a poly(methyl methacrylate) (PMMA) microchip (without contacting the solution) and measuring the impedance of the solution in the separation chann...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 26 7  شماره 

صفحات  -

تاریخ انتشار 2010