Simple Lactate Measurement in Horses Using a Portable Lactate Analyzer with Lancet Skin Punctures under Field Conditions

نویسنده

  • Mitsutoshi KOBAYASHI
چکیده

J. Equine Sci. Vol. 18, No. 1 pp. 5–11, 2007 The following items were investigated to measure blood lactate in horses under field conditions using portable lactate analyzers recently developed for human athletes. 1) The precision of two types of portable lactate analyzer and the standard analyzer using the immobilized enzyme method, and correlation among the lactate concentrations measured by the three lactate analyzers. 2) The correlation between the lactate concentrations in peripheral blood collected by lancet puncture and jugular venous blood using Lactate-pro (L-pro). The study was performed in Thoroughbreds under training for races, using Accusport (AC) and L-pro as portable lactate analyzers and YSI1500 (YSI) for the standard analyzer using the immobilized enzyme method. The intraand inter-assay coefficients of variation (CV) of L-pro was lower than AC at low and middle lactate concentrations. The precision of L-pro is better than AC when the blood lactate level is lower than 10 mmol/l, and hematocrit (Ht) is 57% or lower. The lactate concentration using L-pro in peripheral blood collected by lancet puncture through the neck skin was similar to the level in jugular venous blood. No infection or inflammatory symptom occurred after blood sampling and the examination is relatively safe. These findings suggest that blood lactate measurement using L-pro by lancet puncture through the neck skin under field conditions is simple and safe, requiring no blood sampling from the jugular vein, and it can be used for evaluation of aerobic capacity and intensity of exercise in daily submaximal training.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blood gas, oxygen saturation, pH, and lactate values in elasmobranch blood measured with a commercially available portable clinical analyzer and standard laboratory instruments.

Blood gas, pH, and lactate data are often used to assess the physiological status and health of fish and can often be most valuable when blood samples are analyzed immediately after collection. Portable clinical analyzers allow these measurements to be made easily in the field. However, these instruments are designed for clinical use and thus process samples at 37 degrees C. A few studies have ...

متن کامل

The Effect of Inadequate Presample Blood Volume Withdrawal from Intravenous Catheter and Extension Sets on Measured Circulating L‐Blood Lactate Concentration in Horses Receiving Lactated Ringer's Solution

BACKGROUND Circulating l-lactate concentration is commonly measured in hospitalized horses by sampling from indwelling intravenous (IV) catheters. However, there are no published evidence-based recommendations to prevent contamination by lactated Ringer's solution (LRS). HYPOTHESIS Withdrawing 10 mL of blood from the LRS-containing extension set connected to the IV catheter before obtaining t...

متن کامل

A method-comparison study regarding the validity and reliability of the Lactate Plus analyzer

OBJECTIVES The aims of this study were to: (1) determine the validity and reliability of the Nova Biomedical Lactate Plus portable analyzer, and quantify any fixed or proportional bias; (2) determine the effect of any bias on the determination of the lactate threshold and (3) determine the effect that blood sampling methods have on validity and reliability. DESIGN In this method comparison st...

متن کامل

Portable lactate analyzer for measuring lactate in cerebrospinal fluid (CSF) and plasma - method-comparison evaluations.

UNLABELLED Increased plasma lactate levels can indicate the presence of metabolic disorders in HIV infected individuals. OBJECTIVE To determine whether a portable analyzer is valid for measuring cerebrospinal fluid (CSF) and plasma lactate levels in HIV infected individuals. METHOD CSF and plasma were collected from 178 subjects. Samples tested by the Accutrend portable analyzer were compar...

متن کامل

The efficacy of IPL and ammonium lactate 14% versus ammonium lactate alone in the treatment of keratosis pilaris

Background: Keratosis rubra pilaris is a common condition with an estimated percentage of 40% involvement in the population. This condition is inherited as an autosomal dominant trait and more commonly involves patients with dry skin. In the current study, we evaluated the efficacy of intense pulsed light (IPL) plus ammonium lactate versus ammonium lactate alone in the treatmen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007