Determination of ethanol using flow injection enthalpimetry.

نویسندگان

  • W A de Oliveira
  • C Pasquini
چکیده

A flow injection enthalpimetric method for the determination of ethanol in fuel-grade ethanol, based on the heat of dilution of ethanol, is described. The accuracy and precision were 0.05% of ethanol; interferences by several substances are discussed. A similar procedure was also applied to the determination of ethanol in wines and spirits after distillation, yielding a precision of 0.0%0.1% of ethanol. The sampling rate in both procedures is 110 h-1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FLOW INJECTIOW DETERMINATION OF FLUORIDE BY MURTN-ALUMINUM REAGEM WITH SPECTROEUORIMIETRIC DETECTION

A flow injection system is reported for the determination of fluoride based on its effects on the fluorescence intensity of Al-morin complex at pH 3.0 in ethanol-warn mixture. The effect of important parameters such as excitation and emission wavelengths, pH, reagents concenkations, flow rate of the carrier stream, sample injection volume, time of measurepent and interferences are reported. ...

متن کامل

Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine

A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...

متن کامل

Flow Injection Spectrophotometric Determination of Sulphide by Catalytic Reduction of Toluidine Blue

Sulphide was determined spectrophotometrically at 628 nm and pH 6.7 based on its catalytic reduction of toluidine blue in the presence of Se(IV) using a flow injection system. After optimization of the measuring conditions the calibration curve was found linear up to 25 mg/mL and the detection limit was 0.3 mg/mL (30 mL injections). The ...

متن کامل

Fluorometric determination of ethanol in liquor samples by flow-injection analysis using an immobilized enzyme-reactor column with packing prepared by coupling alcohol oxidase and peroxidase onto chitosan beads.

A flow-injection system was developed for the determination of ethanol with an immobilized enzyme-reactor column. This system, which consisted of hand-made reactor columns packed with alcohol oxidase and horseradish peroxidase immobilized onto chitosan beads, and a fluorometric detector, was applied to the determination of ethanol in liquor samples. Under the recommended conditions, the ethanol...

متن کامل

Enzymatic determination of ethanol and glycerol by flow injection parallel multi-site detection

A flow injection method was developed for the sequential enzymatic determination of ethanol and glycerol in wines, using immobilised ethanol dehydrogenase and glycerol dehydrogenase, respectively. The enzymes were immobilised separately on alkylaminated controlled pore glass. A multi-site spectrophotometric detection system was used in parallel configuration to monitor the absorbance change in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 113 2  شماره 

صفحات  -

تاریخ انتشار 1988