Improved Selective Harmonics Elimination Scheme with Compensation for High-Power PWM Converters
ثبت نشده
چکیده
To reduce the high-order harmonics produced by the high-power pulse width modulated (PWM) converters, selective harmonic elimination (SHE) scheme is commonly used due to its superior harmonic performance at low switching frequency. This Project proposes an active compensation method through the PWM control of SHE phase angle. An application example on a high-power PWM current-source rectifier (CSR) system is provided in this paper. Experimental results show that the proposed method can effectively attenuate the line current harmonics caused by the grid background harmonics in the high-power PWM CSR systems.
منابع مشابه
Conduction and Dead-Time Voltage Drops Estimation of Asymmetric Cascaded H-Bridge Converters Utilizing Level-Shifted PWM Scheme
Linear AC power supplies can be replaced by their nonlinear switching counterparts due to the lower voltage drops and higher efficiency and power density of switching-mode inverters. Multilevel cascaded H-bridge (CHB) converters are the preferred inverter structure because of modular configuration, control, and protection. The output voltage quality in CHB converters depends on the number of ou...
متن کاملحذف هارمونیک های انتخابی مراتب بالا در مبدل های چندسطحی با استفاده از الگوریتم مهاجرت پرندگان
This paper presents a new method to find the optimum switching angles in voltage source multilevel converters in order to minimize specific higher order harmonics and decrease the total harmonic distortion (THD) of their output voltage waveform. The output voltage waveform of inverter can either be in the form of staircase or PWM. In order to increase the degrees of freedom and elimination of m...
متن کاملA New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)
This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...
متن کاملA Review on Dead-Time Effects in PWM Inverters and Various Elimination Techniques
Dead-time is necessary to prevent the short circuit of the power supply in PWM Inverters or converters. But, it will result in output voltage deviations and in case of lower values of current, lower order harmonics will be taken into account. So, dead-time elimination is required in all PWM Inverters or converters. This paper is dealing with a summary of dead-time effects in PWM inverters and v...
متن کاملModified Bi-directional AC/DC Power Converter with Power Factor Correction
Most existing power converters and industrial motor drive systems draw non-sinusoidal currents from the supply. Non-sinusoidal currents contained harm harmonics disturb the power supply which it causes serious concern for reliability. Other equipments that use the same power supply are adversely affected. This paper suggests the operation and performance of a new modified AC/DC converter that ...
متن کامل