Complications of hydroxyapatite pegging: comparison between polycarbonate and titanium peg system.
نویسندگان
چکیده
PURPOSE Polycarbonate peg has been customarily used for pegging of hydroxyapatite for years. For better movement, tissue tolerance, and to decrease the complications of pegging, titanium peg system has been used. This study compares the two systems. METHODS Complications associated with pegging (polycarbonate: Bio-Eye or titanium: Dr-Perry new P-K) were retrospectively reviewed from the charts of 153 patients admitted to the Labbafinejad Medical Center, Tehran, Iran, for over 5 years from 1997 to 2003. RESULTS A total of 153 cases were studied. Ninety-six (62.3%) were male and 57 (37.7%) were female, and the mean age was 27.7 years (6-59 years). In 88 cases pegs were poly-carbonate and sleeve system and in 65 cases pegs were titanium. Forty-one (46%) of cases with polycarbonate and 18 (27%) of cases with titanium had at least one or more complications (p=0.018). The most common complications were granulation tissue, discharge, overgrowth of conjunctiva, and peg falling out in 25%, 23%, 13%, and 8% in polycarbonate peg and 15%, 5%, 1.5%, and 0% in titanium peg group. The prevalence of the last three complications was statistically lower in titanium peg compared with polycarbonate. Twenty-five cases (35%) with polycarbonate peg and 5 cases (7.5%) with titanium peg had two or more complications (p=0.03). Peg removal was done in 11 cases of polycarbonate but only two cases of titanium peg in order to treat the complication. CONCLUSIONS Both pegging systems had some complications, although these were less severe and prevalent in titanium peg. More studies on complications due to titanium pegs are recommended.
منابع مشابه
Complications of motility peg placement for porous hydroxyapatite orbital implants.
AIM To evaluate the complications associated with pegging of porous hydroxyapatite orbital implants. METHODS Complications associated with pegging were retrospectively reviewed from the charts of 100 of 133 patients with hydroxyapatite implantation from 1993 to 2000. RESULTS 48 (48%) of the 100 hydroxyapatite implanted patients who had undergone pegging were found to have problems with thei...
متن کاملComplications in motility PEG placement for hydroxyapatite orbital implant in anophthalmic socket.
PURPOSE In a retrospective study, we evaluated the complications in using the motility peg system (nonsleeved and sleeved) for hydroxyapatite orbital implants in an anophthalmic socket. METHODS Drilling for motility peg placement was performed in 265 patients with hydroxyapatite implantation: nonsleeved peg system (n = 191), sleeved peg system (n = 74). A statistical analysis was performed us...
متن کاملPegging Numbers For Various Tree Graphs
In the game of pegging, each vertex of a graph is considered a hole into which a peg can be placed. A pegging move is performed by jumping one peg over another peg, and then removing the peg that has been jumped over from the graph. We define the pegging number as the smallest number of pegs needed to reach all the vertices in a graph no matter what the distribution. Similarly, the optimal-pegg...
متن کاملTitanium versus Hydroxyapatite Prostheses: Comparison of Hearing and Anatomical Outcomes after Ossicular Chain Reconstruction.
Objective This study aimed to compare hearing and anatomical outcomes after ossicular chain reconstruction with titanium or hydroxyapatite prostheses. Methods In this study, patients who underwent tympanoplasty and ossicular chain reconstruction with titanium or hydroxyapatite prostheses at a university hospital from January 2007 to February 2013 were retrospectively reviewed; they had a mini...
متن کاملGraph pegging numbers
In graph pegging, we view each vertex of a graph as a hole into which a peg can be placed, with checker-like “pegging moves” allowed. Motivated by well-studied questions in graph pebbling, we introduce two pegging quantities. The pegging number (respectively, the optimal pegging number) of a graph is the minimum number of pegs such that for every (respectively, some) distribution of that many p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of ophthalmology
دوره 17 3 شماره
صفحات -
تاریخ انتشار 2007