Calcium Optical Frequency Standardresearch at Ptb

نویسندگان

  • U. Sterr
  • G. Wilpers
  • T. Binnewies
  • C. Degenhardt
  • J. Helmcke
  • F. Riehle
چکیده

At PTB we have developed an optical frequency standard based on laser cooled calcium atoms. A laser is frequencystabilized to the intercombination transition at a wavelength of 657 nm by means of time-domain atom interferences. The dependence of its frequency on various parameters was investigated by using different excitation schemes corresponding to phase sensitive and frequency sensitive atom interferometers. At present the total relative uncertainty of the measured frequency amounts to 2·10. As a result the Ca stabilized laser is among the optical frequency standards of lowest uncertainties. Further improvements using ultracold atoms are demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The optical calcium frequency standards of PTB and NIST ⋆ Les étalons de fréquence optique au calcium de la PTB et du NIST

We describe the current status of the Ca optical frequency standards with laser-cooled neutral atoms realized in two different laboratories for the purpose of developing a possible future optical atomic clock. Frequency measurements performed at the Physikalisch-Technische Bundesanstalt (PTB) and the National Institute of Standards and Technology (NIST) make the frequency of the clock transitio...

متن کامل

A Calcium Optical Frequency Standard with Ultracold Atoms: Approaching 10−15 Relative Uncertainty

An optical frequency standard based on an ensemble of neutral calcium atoms laser-cooled to 12 μK has been realized. By using ultracold atoms, one major previous source of uncertainty, the residual Doppler effect, was reduced. We show that cold collisions contribute a negligible amount to the uncertainty. The influence of a temporal evolution of the phase of the laser pulses used to interrogate...

متن کامل

Stray-field-induced quadrupole shift and absolute frequency of the 688-THz

We report experimental investigations of a single-ion optical frequency standard based on Yb+. The ion is confined in a cylindrically symmetric radiofrequency Paul trap. The reference transition is the S1/2 F=0 – D3/2 F =2 electric quadrupole transition at 688 THz. Using a differential measurement scheme, we determine the shift of the reference transition frequency that occurs due to the intera...

متن کامل

Uncertainty evaluation of the caesium fountain clock PTB-CSF2

The uncertainty evaluation of CSF2, the second caesium fountain primary frequency standard at PTB, is presented. The fountain uses optical molasses to cool atoms down to 0.6μK. The atoms are launched vertically in a moving optical molasses, and state-selected in the |F = 3,mF = 0〉 hyperfine ground state. During their ballistic flight, the atoms interact twice with a microwave field, thus comple...

متن کامل

Status of Vitamin D, Calcium and Parathyroid Hormone Levels & Hepatorenal Function in Untreated Pulmonary Tuberculosis: A Matched Case-Control Study

Background and Objective: Tuberculosis (TB) remains an ongoing major public health problem in the world. In recent years, experimental evidenc suggests a link between TB and Vitamin (Vit) D. This study was conducted to determine serum Vit D, calcium (Ca), phosphorus (P), and parathormone (PTH) levels in untreated pulmonary TB (PTB) patients. Materials and Methods: In this case control study, 5...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002